Today Starlight Power generator manufacturer mainly talk about troubleshooting of turbocharger for diesel generating sets, hope it is helpful to you. Whether technical maintenance personnel of generator, or operator, maybe do not know why genset turbocharger is easy to cause fault. The requirements for lubrication, cooling and sealing of turbocharger are relatively high. In order to ensure the service life of the turbocharger, the lubrication and cooling of the floating bearing of the turbocharger should be ensured. At the same time, we should do: 1.The engine should run at idle speed for 3-5 minutes after starting. Do not add load immediately to ensure good lubrication of turbocharger. The main reason is that the turbocharger is located on the top of the engine. If the turbocharger runs at high speed immediately after starting, the oil pressure will not be increased in time to supply oil to the turbocharger, resulting in fuel shortage and damage to the turbo...