6.1 Lubrication System 6.1.1 Oil Change Intervals - Deutz Diesel Engine The first oil change after commissioning or recommissioning following repair work is carried out after 50 running hours. The oil change intervals are depending on Lube oil quality and engine application. Should, within a year, the engine runs less than the hours stated in the table (250 h), the oil must be changed at least once a year. The table refers to the following conditions: - For diesel fuel max.sulfur content >0.5% by wt. - Continuous ambient temperature down to -10°C If the sulfur content is from 0.5% to 1%, or the continuous ambient temperature below -10°C, the intervals between the oil changes should be halved. In case of fuels containing sulfur >1%, ask your service representative. Note: Change the oil with the engine shutdown but still warm (lube oil temp.approx.80°C) 6.1.2 Check Oil Level/ Changing Engine Oil 6.1.2.1 Checking Oil Level Ensure that the engine o...