Checking signal Cable Rail Pressure Sensor of Volvo Engine Tools: 885675 Break-out cable 88890074 Multimeter 1 Cut the current with the main switch. 2 Disconnect the connector from the sensor. 3 Connect break-out cable 885675 to the cable harness connector to the engine control unit. 4 Use multimeter 88890074 to do resistance measurement against the engine control unit. NOTICE! Measurement is done to eliminate short circuiting or breaks in the cable to the engine control unit. Checking injection control pressure sensor Tools: 885675 Break-out cable 88890074 Multimeter 1 Turn ignition off. 2 Disconnect the connector from the sensor. 3 Connect break-out cable 885675 between the sensor and the engine control unit. 4 Use multimeter 88890074 for voltage measurement. 5 Turn ignition on. Checking the wiring to the MPROP valve Tools: 88890074 Multimeter NOTICE! If any of the measurements shows an...