DCEC Cummins B Series Diesel Engine Introduction

Dongfeng Cummins B series diesel engine is a product of Cummins Inc, introduced by Dongfeng Motor Corporation through technology transfer in 1987. Cummins Inc. (CUMMINS) is one of the largest diesel engine manufacturers in the United States. Founded in 1919, the company has developed a variety of world-famous, technologically leading diesel engines, and its product quality and performance enjoy a high reputation in the world. Dongfeng Company and Cummins USA formed a joint venture company in 2003 - Dongfeng Cummins Engine Co., Ltd. Dongfeng Cummins B series diesel engines are well known internationally. With supercharged and supercharged intercooling as the basic models, it has eight characteristics: reliable, durable, emission and noise meet US regulations, advanced performance index, wide application range, good applicability, low cost, convenient maintenance and repair. Cummins Medium Power Diesel Engine in China In 1986, Cummins and Dongfeng Motor Co. signed a co...

Monthly Cleaning and Inspection of Deutz Diesel Generator in Summer

Fuel filters of Deutz generator set work for 100 hours and mailboxes work for 500 hours, each cleaning once. If the filter core is found to be broken, it should be replaced in time, instead of demolishing it to adopted direct current oil supply. Couple parts should be disassembled and inspected once when they work under normal working conditions for 500 hours. When disassembling and inspecting, make sure the place, hands, tools and cleaning oil are clean so as to avoid contamination of couple parts. In the disassembly operation, do not knock. When cleaning, do not pile up or wash with other non-accidental parts in order to avoid bruising or abrasion. When assembling, it is not allowed to change the position of assembling at will so as to achieve certain purposes that do not meet the requirements of the machine. When installing the oil valve seat and nozzle cap, tightening should be done according to the prescribed moment to ensure the assembled injector.   1.Clean th...

Is It Better to Let a Perkins Diesel Generator Set Idle?

In generally, it is no problem to let diesel generator set idle no more than 10 minutes. If idling for a long time, will cause diesel engine damage. In this article, we mainly talk about idling of Perkins generator. 1.What is diesel generator set idling? Idle state, that means diesel generator set work without any load. That is to say, under this working condition, the generating set does not need to bear load, as long as it keeps the low speed required for smooth operation.  2.   Why can not let Perkins diesel generator set idle for a long time? A.   If Perkins diesel generator set idles for a long time, it will also reduce the quality of fuel injection atomization, accelerate early wear of cylinder wall. Because the quality of atomization is directly related to the injection pressure, injector aperture and camshaft speed of Perkins diesel generator set. Because the injector aperture remains unchanged, the quality of fuel atomization depends on the ...