The reasons of diesel engine oil mixing in diesel genset

The diesel and engine oil of diesel generator set have completely different functions. They can not be mixed. Once they are mixed, it means that the sealing of the genset is faulty during working.   Maybe you meet this problem, today Starlight Power tell you how to deal with it. We should deal with it according to different situation .   1.The film of oil transfer pump decays or degumms, causing diesel oil to flow into the oil pan and mix with oil. Remove the oil transfer pump and apply corresponding pressure to the oil inlet and outlet pipes on the oil pump test bench. If no diesel leakage, it indicates the oil transfer pump is in good condition. 2.The opening pressure of injector is low and poor atomization, causing the diesel oil to flow into the oil pan along the cylinder wall and mixes with the oil.   Remove the injector and test it on the high-pressure oil pump test bench. If the opening pressure of the injector meets the requirements and the atomization is good, in...

Feature of Yuchai engine YC16VC and YC4R for Diesel Genset

1.Yuchai engine YC16VC series for diesel generator sets Yc16vc series engine is a high-power V-type product independently developed by Yuchai. It has the advantages of compact structure, excellent performance, energy conservation and environmental protection, reliability and durability, etc., and the emission pollutants, power, economy and reliability indexes have reached the international advanced level. Feature a.The engine body is made of high-strength material, arc stiffener grid structure, four bolt main bearing structure, with high rigidity, small vibration and low noise. b.The crankshaft is made of high-quality alloy steel with all fiber extrusion forging, shaft diameter and fillet quenching heat treatment, anti-wear and long service life. c.It adopts electronic control single pump, four valve, high efficiency supercharging and intercooling, Yuchai combustion chamber technology, with low fuel consumption, less emissions, excellent speed regulation...

Do you know standby diesel generators

Standby generator set: In the normal case, the power required by the user is supplied by the mains, and when the mains is cut off or the power is interrupted for other reasons, the generator set is set up to ensure the basic production and life of the user. Such generator sets are mainly located in telecommunications departments, hospitals, industrial and mining enterprises with tight supply of electricity, airports and TV stations. This kind of unit maintains the standby state at any time, can provide the continuous power supply to the non-constant load. With the development of science and technology, some power users and electrical equipment have higher and higher requirements for the reliability of power supply. In order to ensure the reliability of power supply, some important users such as hospitals, data centers, and communication hubs have set up standby generators in their power supply systems in addition to dual power supply (ATS), and some even set up UPS. To ensure unin...

Starlight Volvo Diesel Generator Tier 2 and Tier 3 Engine Models

Volvo Penta Genset Engine - A powerful, reliable and economical Generating Set Diesel Engine built on the dependable in-line four design. Starlight will share Volvo generator engine models as well as corresponding power in the table below. (Including T2 and T3 emissions, 50Hz/60Hz) Volvo Generator Stage II/ Tier 2 Features: Energy efficiency and Economy Through careful management of the combustion process, involving precise control of air movement and injection spray Volvo Penta has been able to achieve high efficiency and reduced exhaust emission levels that comply with current requirements and which will enable the engines to satisfy future legislation. Volvo Penta engines offer the highest kWh/Liter fuel, resulting in superior economy and performance. Durability & low noise Designed for easy, fast and economical installation. Field tested to ensure highest standard of durability and long life. Well-balanced to ...

Is It Better to Let a Perkins Diesel Generator Set Idle?

In generally, it is no problem to let diesel generator set idle no more than 10 minutes. If idling for a long time, will cause diesel engine damage. In this article, we mainly talk about idling of Perkins generator. 1.What is diesel generator set idling? Idle state, that means diesel generator set work without any load. That is to say, under this working condition, the generating set does not need to bear load, as long as it keeps the low speed required for smooth operation.  2.   Why can not let Perkins diesel generator set idle for a long time? A.   If Perkins diesel generator set idles for a long time, it will also reduce the quality of fuel injection atomization, accelerate early wear of cylinder wall. Because the quality of atomization is directly related to the injection pressure, injector aperture and camshaft speed of Perkins diesel generator set. Because the injector aperture remains unchanged, the quality of fuel atomization depends on the ...