High Quality New 800kw Generators

Deliver New Electric Diesel Genset to Customers

Do you know standby diesel generators

Standby generator set: In the normal case, the power required by the user is supplied by the mains, and when the mains is cut off or the power is interrupted for other reasons, the generator set is set up to ensure the basic production and life of the user. Such generator sets are mainly located in telecommunications departments, hospitals, industrial and mining enterprises with tight supply of electricity, airports and TV stations. This kind of unit maintains the standby state at any time, can provide the continuous power supply to the non-constant load. With the development of science and technology, some power users and electrical equipment have higher and higher requirements for the reliability of power supply. In order to ensure the reliability of power supply, some important users such as hospitals, data centers, and communication hubs have set up standby generators in their power supply systems in addition to dual power supply (ATS), and some even set up UPS. To ensure unin...

The Difference: Water-cooled Generator VS Air-cooled Generator

The cooling way of diesel generator has water-cooled and air-cooled, what is the difference between water-cooled generator and air-cooled generator? Here is something you should know. Water-cooled Diesel Generator: Its cooling system uses water as the cooling medium, and then dissipates heat through cooling water tank and fan to ensure the normal working temperature of the diesel engine. The water cooling system consists of water pump, radiator, fan, thermostat, water jacket and water pipe. The coolant of the   water cooling system   is located in the water jacket of the engine. The temperature of the high temperature machine is absorbed and the temperature rises, the radiator is cooled by fans and upwind airflow, and then the coolant is pumped into the water jacket for cyclic cooling.  There are two ways of circulating coolant: the thermostat closes when the engine water temperature is below 70 °C, coolant flows through pump, water jacket, heater bypass pi...

Working Conditions of Weichai Diesel Engine for Power Generation

3.10 Power Definition and Working Conditions of Weichai Diesel Engine for Power Generation 3.10.1 Power definition Continuous Power COP In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under constant load.ISO standard power. Normal Power PRP In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under variable load. ISO standard power which can overload by 10%. Standby Power ESP Maximum power in some variable power series with annual running time of diesel engine up to 200h.ISO standard power with limited fuel volume. 3.10.2 Running Conditions and Applications of Power Running conditions and applications of different powers of diesel engine are as shown in Table 3-1.   Ambiance condition The diesel engine should be able to output rated power in the following conditions. Atmospheric pressure, PX:100kPa (or 0 meter above sea lev...

Terminal Pillars Letters Meaning in Deutz Generator Set

In generally, there is terminal pillars in generator, such as armature, magnetic field, tower, neutral point, etc. These terminal pillars have different letters, what does the letters mean? Today Starlight manufacturer talks about terminal pillars letters meaning in Deutz generator set. 1.   Armature terminal pillars. It is a coarser terminal pillars in generator, in generally, its diameter is 6mm; 2.   Magnetic field terminal pillars and neutral point terminal pillars. There are two buttons on the generator, usually 3 mm in diameter. One of the screw roots contacts directly with the outside or connects with conductive copper sheet, which is a tower terminal pillars. Another adjacent thin terminal is the magnetic field terminal, and an independent terminal is the neutral point terminal; 3.   Use multimeter to measure and identify. Before measure, remove the wires on the terminal pillars of the generator, place the multimeter in RX10 gear and RX100 gear, then one w...