3.10 Power Definition and Working Conditions of Weichai Diesel Engine for Power Generation

3.10.1 Power definition
Continuous Power COP
In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under constant load.ISO standard power.
Normal Power PRP
In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under variable load. ISO standard power which can overload by 10%.
Standby Power ESP
Maximum power in some variable power series with annual running time of diesel engine up to 200h.ISO standard power with limited fuel volume.

3.10.2 Running Conditions and Applications of Power
Running conditions and applications of different powers of diesel engine are as shown in Table 3-1.




Ambiance condition
The diesel engine should be able to output rated power in the following conditions.
Atmospheric pressure, PX:100kPa (or 0 meter above sea level);
Ambiance temperature , Tr: 298K(25℃);
Relative air humidityΦr: 30%
The diesel engine should be able to work continuously and reliably in the following conditions:
Range of ambiance temperature: -30℃≤T≤50℃;
Relative air humidity: the max relative humidity is 90% of the wettest month in a year(It means that the lowest average temperature of this month is 25℃).
The working environment should be without explosive gas and electric mote.
The customer should illuminate in advance if there has any especial and dangerous condition at the working space (for example, explosive and flammable gas).

Starlight can provide 20kw to 1000KW Weichai diesel generator with Stamford/Marathon/Engga/Leroy-Somer/Shanghai KEPU alternator optional. Weichai has sales service centers in many countries. It is easy to get spare parts when needed.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz