Skip to main content

Posts

Showing posts with the label 500KW Volvo diesel generator

Archive

Show more

500kw Volvo Diesel Generator Runs for A Long Time

If we can inspect and maintain 500kw Volvo generator after it runs for a long time, we will reduce more unnecessary troubles. So, how we should inspect and maintain? Please follow us. 1.Primary technical maintenance: 50-80 hours.   (Added to the content of daily maintenance) A. Replace and clean air filter if necessary. The air filter is an unconspicuous but important part of the whole diesel generator set. Once the air filter is too dirty, it may cause serious mechanical accidents, especially in the environment and areas with poor air quality. In order to avoid shortening the service life of diesel generator, after shutdown, check the air filter in time and whether the air filter is blockage and damage. If so, clean and replace it in time. B. Check and replace the fuel filter and water filter; C. Check the tension of the drive belt; D. Add lubricating oil to all oil injection nozzles and lubricating parts; E. Replace cooling water. 2.Secondary technical main...