Perkins Syncro 1.7 and 2.2 Litre Electronic Products Deliver Optimized Performance

Rental, a U.S. magazine serving equipment rental professionals for the past 39 years, has selected the Perkins® Syncro 1.7 and 2.2 litre as recipients of one of its 2017 Editor ’ s Choice Awards. The Perkins Syncro 1.7 and 2.2 litre was chosen as a winner for the 2017 Editor ’ s Choice Awards based on several factors including innovation, utility for the rental market, and audience engagement online at ForConstructionPros.com/Rental. A range of compact engines, the Perkins Syncro 1.7 and 2.2 litre electronic products deliver optimised performance for today ’ s rental market. Our durable engines are designed and tested to consistently meet the demands of rental machinery. Power from the Perkins  Syncro 2.2 litre, 4 cylinder turbocharged aftercooled model has been boosted to 50 kW (67 hp) with a maximum torque of 208 Nm at 1800 rpm, while rated speed is up to 2800 rpm. Customers also have the option of a turbocharged model offering up to 36 kW (48 hp). Performance...

Steps to Correctly Use A Diesel Generator

Learning how to correctly start a diesel generator is not an easy thing. Starting incorrectly, it may have a bad effect on the diesel generator set. It can be said that correct steps are the precondition to guarantee the normal operation of the unit. Then what are the correct steps to start a diesel generator? Through reading this article, you will get the answer. 1. Check whether the water tank is full of water. In winter, check whether the antifreeze is full 2. Check the oil level, fuel level, and radiator water level. If the level is lower than the specified value, it should be added to the normal position. 3. Check whether all the switch position is correct to meet the start requirements. 4. Check whether the diesel genset “ Emergency Stop ” button on the dashboard is correct. 5. Check whether the outlet switch of the unit is off-position. 6. Check whether the genset preheating is normal. When the indoor temperature is lower than 20 degree Celsius, the electric h...

Why Diesel Generator Fail to Start

After using a diesel generator for a long time, some malfunctions may occur that will cause the generator fail to start. What can you do when it happens? If diesel generators fail to start, you can analyze the causes from fuel system failure, electric starting system failure, insufficient compression pressure in the cylinder and the low ambient temperature and other factors. Fuel System Failure 1. Air in the fuel system This is a common problem that a diesel generator fails to start normally. Solution: Check whether the fuel oil pipe connector is loose or not, and ensure that the air is cleared from the fuel system. Loosen the bleed screw bolt on the diesel filter, and then use the manual oil pump to pump the fuel until the air bubble is gone. 2. Fuel Line Obstruction Solution: Check whether the pipeline is smooth or not. 3. Fuel Filter Clogging Solution: Clean the filter or replace the filter element 4. The Handle Position of Fuel Injection P...