EGS-02 Gas Electronic Control Advantages

-The generator set has good starting performance Because the EGS-02 control system realizes the closed-loop control of the running process, it ensures that the control system can be quickly controlled to a suitable air-fuel ratio state through the adjustment of the system, and the system can start quickly. Through one operator can realize the start of the unit, and do not need to adjust repeatedly, a success. The WOODWARD automatic controller system of 1100GFRQ gas generator can also realize the function of self-starting. The process is as follows: starting according to torsion-presupply oil-unit starting-idling running-rated rotational speed running-automatic grid-connected automatic load-stable operation. -Realize lean combustion, prevent intake pipe from tempering, improve efficiency and reduce heat load WOODWARD combustion control system  collects signals of methane concentration and oxygen content in exhaust gas by methane sensor and oxygen ...

Generator Set Repair and Maintenance

6.1 General Provisions Good maintenance and repair, the key of the long-term service life of the generator set, should be carried out by the qualified technical personnel. Good record shall be made in case of maintenance and repair, which will be helpful to arranging the working procedures of maintenance and repair in the future. In general, the generator set  shall be kept clean without liquids such as: fuel oil or lubricating oil piled up on any internal or external surfaces and on the surface of, under and around the sound absorption (if the device is available) materials. The industrial water solvent shall be used to clean the surface of the machine, but the flammable solvents can not be used for cleaning. For instance, the protection of the sound absorption material is torn down or penetrated, it should be replaced immediately so as to prevent the liquid or oils penetrated and accumulated on the material. 6.2 Preventative Maintenance For the situations of the use...

Instructions to Start And Stop Diesel Generator Set

5.3Initial start/stop----Automatic start control panel (initial start and stop) The following procedures are applicable for the initial start of the electric generating set configured with automatic start control system or the first start after a period maintenance of the generating set. Notice : *Press the emergency button or switch the control switch to “ STOP ” to stop the engine at any time. *Before restart, release the emergency stop button and rotate clockwise. Meanwhile, switch the control switch manually to “ STOP ” . 1. Examine before start the machine according to Chapter 5.2 2. Connect battery to the engine, first positive electrode and then load. 3. Check whether the engine oil is filled to the assigned level. 4. Check whether water is filled. 5. Discharge the air in fuel system. ! Connect and start the abnormal fueling system will cause unburned oil accumulated in the smoke evacuation system, bringing potential explosion risk...