Part 2: Solutions for faults of electrical control system of diesel genset

4.Low oil pressure fault alarm or shutdown A.Check the oil level; B.Check oil quality and viscosity; C.Check the oil temperature; D.Check whether the oil pressure sensor is damaged; E.Check whether the oil filter and oil circuit are blocked; F.Check whether the oil pressure sensor switch alarm is correct. 5.Overspeed fault causes shutdown A.Check the speed meter to indicate if there is any abnormality; B.For mechanical speed control mechanisms, check the throttle lever for flexibility and ensure proper adjustment; C.For the electronic speed control system, check if the throttle lever is flexible and check whether the actuator is operating correctly; D.Recalibrate and adjust the overspeed protection limit; E.Check if the speed sensor installation is reasonable; F.Reset the alarm signal on the control panel after troubleshooting. 6.High voltage alarm A.Measure the actual value of the unit's output voltage; B.Confirm that the meter is not biased;

Brushless AC generator production workshop--Starlight Power factory

Delivery 800kw Prime Yuchai Power Generator to Client

Part 1: Solutions for faults of electrical control in diesel generator

This article mainly talks about how to solve the faults of electrical control in diesel generator set. 1.When the key is turned to “START” for the manual control genset, the genset does not start or the liquid crystal display module controls the genset, and the genset does not start when turn on the start button. A.Check whether the key switch is working correctly or whether the module start-up port has output; B.Check whether there is any fault indication, repair the fault if necessary, and reset the corresponding fault information; C.Check the battery voltage. If the voltage is too low, you need to recharge the battery to full. If the voltage value is normal, you should gradually check whether the voltage signal is correctly sent to all control links according to the drawing, such as throttle solenoid valve and starter motor etc; D.Check if the emergency stop button has been relaxed; E.Check whether the start relay good. 2.Start motor, it can work, but th

300kw Ricardo three phase generator set

What is Protection Grade of Diesel Generator

When you choose a diesel generator, its protection grade also is an important factor that you should consider. What is protection grade? Protection grade also called ingress protection( IP), this system is written by IEC ( international electrotechnical commission), indicating the level of dust-proof and moisture-proof of electrical equipment. Protection grade consists of two number, the bigger the number is, the higher the level of protection. Indicating methods: The protection grade usually is indicated by IP and two number, the number indicates the protection level. The first number indicates the range of dust resistance of the equipment, or the extent to which people are protected from hazards in a sealed environment. Represents a level to prevent solid foreign bodies from entering, the highest level is 6. The second number indicates the degree of waterproofing of the equipment. Represents the level of water intake prevention. The highest level is 8. We s