Skip to main content

Posts

Showing posts from December 29, 2019

Archive

Show more

1000kw/1250kva Silent Cummins Electric Diesel Generator with Stamford al...

What are the common failure types of cylinder of silent 400kw generator set?

What are the common failure types of cylinder of silent 400kw generator set? Wear is the main failure type of the cylinder of diesel generator set. Whether the internal combustion engine needs to be overhauled or not depends on the wear degree of the cylinder. Therefore, to study the causes of the cylinder wear of the generator set and grasp its wear law is not only of certain significance to test the degree of cylinder wear of the diesel generator set, but also of great importance to take effective measures in the maintenance, management and use of the internal combustion engine in order to reduce the cylinder wear and prolong the service life of diesel engine of 400kw diesel generator set . What is the main regularity of cylinder wear of silent 350kw diesel generator set? 1.The wear in the moving area of piston ring is larger. This kind of wear is uneven, heavy on the top and light on the bottom, making the cylinder "tapered" along the length direction

Heavy Duty Yuchai Diesel Generator Set--Supplied by Starlight Power

Control Panel of Automatic Diesel Generator Sets

What is the description of control system of automatic generator set? The control system is an advanced electronic control system, which installs on generator set to control and monitor its operation and output. Different control systems are provided according to the needs of several different generator sets. They includes   SmartGen control panel   HGM6110 series, HGM6300 series and HGM6400 series automatic start up system. If a special control system is installed due to special needs, an independent information document will be attached. The diesel generator control panel provides generator control switch to monitor its operation and output. Or in an emergency events, for example the generator set will shut down automatically if there is low oil pressure or high coolant temperature. Any series is matched according to the requirements of the generator set. The output circuit switch of the alternator automatically turns off the load to protect the output when the circuit i

Leroy-Somer Alternator R150 AVR of Generator Set

1 - GENERAL DESCRIPTION The Automatic voltage regulator (AVR) is a compact, high performance encapsulated unit. The AVR incorporates latest technology and efficient semiconductor to achieve a high degree of miniaturization when applied to 3Ø and 1Ø AC brushless generator within its input and output limits, the unit offers excellent reliability. The AVR supplies DC excitation to the exciter field of a   brushless generator   to keep the terminal voltage within close limits from NO-LOAD to FULL LOAD. The recovery time on sudden loading is likely to be around 0.5 sec. to recover 98% of the rated voltage. Please note that the transient performance like voltage dip and recovery time are mainly decided by the generator and exciter design parameters. Best performance from the regulator can be obtained by keeping full load excitation around 60V DC. The generator employs true average sensing circuit, dV/dt snubber and special filters circuits to cope with NON-LINEAR loading like batter