Volvo Diesel Generator Fails to Produce Specified Power

When Volvo diesel generator is failure to produce specified power, firstly we should check whether air intake and fuel injection are sufficient, whether the combustion process is normal and the compression pressure is large enough to analyze and judge step by step, find out the cause of the fault and eliminate it. The specific causes and solution methods are as follows: 1.Failure to produce specified power due to failure of valve mechanism and air inlet and exhaust system. Reason: Incorrect clearance between intake, exhaust valves and rocker arms; Incorrect actual opening and closing time of intake and exhaust valves; Valve spring is damaged; The valve has carbon deposits and the sealing surface leaks; Air filter blocked; Exhaust pipe and silencer have serious carbon deposits and poor exhaust. Treatment methods: Check and adjust to specified clearance; Check and adjust the opening and closing time of intake and exhaust valves; Replace new valve spring; ...

How to deal with Volvo diesel generator starting problem

What is the reason of Volvo diesel generator start failure problem? Today Starlight manufacturer solve problem for you. The reason why the diesel engine can't work properly is that we should first understand the primary condition for the normal operation of the diesel engine. We all know that the primary condition for the normal operation of the diesel engine is that the diesel engine with good chemical composition can be injected into the combustion chamber accurately and timely, and that the compressed air in the combustion chamber must reach enough temperature before it can work properly. Fire, eruption. To satisfy these two conditions, it is necessary to have a high enough speed and a certain temperature in the cylinder when starting the diesel engine. When the diesel engine can not start, the reasons should be found from starting work, fuel supply system and compression of the diesel engine. 1.The ambient temperature is too low. At this time, the diesel engine ca...

Starlight Volvo Diesel Generator Tier 2 and Tier 3 Engine Models

Volvo Penta Genset Engine - A powerful, reliable and economical Generating Set Diesel Engine built on the dependable in-line four design. Starlight will share Volvo generator engine models as well as corresponding power in the table below. (Including T2 and T3 emissions, 50Hz/60Hz) Volvo Generator Stage II/ Tier 2 Features: Energy efficiency and Economy Through careful management of the combustion process, involving precise control of air movement and injection spray Volvo Penta has been able to achieve high efficiency and reduced exhaust emission levels that comply with current requirements and which will enable the engines to satisfy future legislation. Volvo Penta engines offer the highest kWh/Liter fuel, resulting in superior economy and performance. Durability & low noise Designed for easy, fast and economical installation. Field tested to ensure highest standard of durability and long life. Well-balanced to ...

Volvo Penta Successful Challenge to Install TWD1645GE Engine In a Prototype Genset

When Volvo Penta produced a new power generation engine, it turned to long-term business partner, Khonaysser Motors, to install the TWD1645GE in a prototype genset. The Lebanese genset manufacturer tasked two of its customers with field-testing the unit, and one year later, the product has proven to be a success. When Lebanese electricity supply company Ishtirak El Hassan needed additional power sources to keep up with demand, it was eager to field-test the new genset from Khonaysser Motors. With an unstable mains electricity supply, Lebanon is frequently subjected to power cuts. To ease the burden, Ishtirak El Hassan uses gensets to produce electricity for small companies, shops, offices and homes. The company began field-testing a new genset equipped with Volvo Penta’s latest power generation diesel engine, the TWD1645GE, in 2017.  “We have been really satisfied with this genset,” says Ali Soufan, owner of Ishtirak El Hassan. “The Volvo Penta engine in Khonays...