Fault diagnosis and troubleshooting method Generator overheating (1) The generator does not operate in accordance with the specified technical conditions, such as too high stator voltage, iron loss increases; if the load current is too large, the copper loss of the stator winding increases; if the frequency is too low, the cooling fan speed becomes slow, affecting the heat dissipation of generator; the power factor is too low, so that the rotor excitation current increases, resulting in the rotor heating. Check whether the indication of monitoring instrument is normal. If it is abnormal, necessary adjustment and treatment must be carried out to operate the generator in accordance with the specified technical conditions. (2) The three-phase load current of the generator is unbalanced, and the overloaded one-phase winding will overheat; if the difference of three-phase current exceeds 10% of the rated current, it is a serious phase current imbalance, and the thre...