New arrival!!! Ricardo and Cummins Diesel Generators

Export ATS Switch Cabinet to Our Ethiopian Customer

ATS (automatic transfer switch) is mainly used in emergency power supply system to automatically switch the load circuit from one power source to another (standby) power source to ensure continuous and reliable operation of important loads. Therefore, ATS is often used in critical power supply places, and its product reliability is particularly important. ATS (Automatic Switching System) control cabinet consists of the following components: A. Core components: automatic power transfer switch B. Control module C. Panel signal indicator and its peripheral circuit. Our Ethiopian customer purchased a total of 3 generator sets from our Starlight company in 2018 and 2019, including 500KW, 600KW and 1000KW Cummins containerized silent diesel generator sets with CSIC Siemens alternator. The ATS purchased this time is Suyang brand ATS, current is 1600A, model is SYK1-1600A/4P. We have successfully delivered to our customer on July 31st. The ATS purchased by the customer i

Should We Often Change Diesel Generator Lubricating Oil

Engine oil is generally used for lubrication, cooling, sealing, heat transfer and rust prevention. The surface of each moving part of the engine is covered with lubricating oil to form an oil film, avoiding the heat and wear of the parts. Regular replacement of oil to ensure the stable operation of diesel generator set. Such maintenance can effectively extend the service life of the diesel genset. Therefore, in the process of using the diesel generating set, it is necessary to determine the replacement time of the genset accurately. How long does it take to replace the oil of the diesel generator? The oil used by different diesel generator manufacturers and   diesel generators   of different power is different. In general, the new engine works for 50 hours for the first time and 50 hours after repair or overhaul. The oil replacement cycle is usually carried out at the same time as the oil filter (filter element). The general oil replacement cycle is 250 hours or one month. Usi

600kw CCEC Electric Generator for Power Generation

Starlight Cummins Diesel Generator Facilitating B&R and Leading Shared Development

On August 2nd, 2019 Asia-Europe Hardware and Electrical Products Trade Fair was held in Xinjiang International Convention and Exhibition Center (Urumqi·Hongguang Mountain). Chongqing Cummins diesel generator set series products jointly launched by Starlight company and Chongqing Cummins engine Co., Ltd. makes a stage pose in this exhibition. Based in Xinjiang, this exhibition covers Central Asia, Russia, and Central and Eastern European markets. Xinjiang is China's bridgehead for the opening and cooperation of countries along the Silk Road in Central Asia, Russia, Central and Eastern Europe, etc. It is also the most convenient way for China's hardware and electrical enterprises to enter the economic and trade relations of Central Asia, Russia, Central and Eastern Europe and other countries along the Silk Road. In recent years, with the in-depth development of national “One Belt One Road” strategic construction, China’s economic and trade relations with these co

What is Common Problems of Cummins Generator Supercharger

Why supercharger is the most vulnerable assembly on Cummins engine? Because the rated working speed of the supercharger is more than 130,000 rpm, and it is at the outlet of the exhaust manifold, the temperature is extremely high (above 800°C), and the inlet and exhaust pressure is also large, high temperature, high pressure and high speed. Therefore, the requirements for lubrication, cooling and sealing of the supercharger are relatively high. In order to ensure the service life of the supercharger, it is necessary to ensure the lubrication and cooling of the turbocharger floating bearing. At the same time, in use, it is required to: a. The engine should idle for 3-5 minutes after starting. Do not add load immediately to ensure good lubrication of the supercharger. The main reason is that the supercharger is located at the top of the engine. If the supercharger starts to run at high speed immediately after the engine starts, it will cause the oil pressure to fail to rise i