50KW Yuchai Diesel Power Generating Set with CE ISO certificate

How to maintain the mobile trailer generator set

  Diesel generator sets are limited to the following maintenance methods: Check the four-leakage phenomenon, surface, starting battery, engine oil and fuel oil of the unit; Clean and improve the environment of the computer room, and replace the three filters regularly; Carry out no-load maintenance every month, and carry out maintenance of loading and test machine every six months; Use power monitoring to observe power quality parameters in real time. Limitations of existing maintenance methods: The load test in the existing maintenance is only the load test of the existing back-end electrical equipment, which has certain risks and low power; There is no scientific basis for replacing the three filters or undergoing major repairs; After replacing the three filters or undergoing major repairs, there is no special load for loading test machine, and it is not clear whether the expected purpose can be achieved; A large amount of carbon deposits produced by no-load test machine and low-powe

Installation skills of mobile generator sets

  Mobile generator set, also known as trailer generator set, can be moved freely and is suitable for large and unfixed workplaces, such as construction sites, large-scale breeding sites, field mining, media outdoor interviews, etc., and can be used as the main power source It can also be used as a backup power supply. Its cover is made of high-quality galvanized sheet, which has the characteristics of corrosion resistance and good sealing. The windows and doors on all sides are supported by automatic hydraulic pressure, which is easy to open. The chassis wheels can be customized according to user needs. The Trailer Generator   is mainly installed on a movable platform such as a car, a trailer or a trailer. The installation and layout requirements are as follows. 1. The platform should be located in a solid, flat and dry place. Under normal circumstances, the platform and the ground do not need to take fixing measures, but the chassis of the unit should be stable. 2. Comprehensively che

Full New 600kva Diesel Generators Powered by CCEC Cummins Engine QSK19-G4

Three Tips for a Successful Installation of a Diesel Generator Set

  What can it cost to set up a   Diesel Generator Set ? That is always the first issue our clients ask. There are lots of things that will dictate the price of an installment, and it is important your installer is acquainted with these variables. Where will the generator be found? Can there be landscaping required? The number of feet of conduit will be required? An preliminary site-walk and load observation are a first measure. Our qualified local electricians can collect onsite information for suitable load sizing, inspection prospective installation places, and gather any information required to permit us to create a proposal for your job. Different towns have very different procedures and requirements. When it's codes, structure, transport, flood zones or after-hour job demands - these affect virtually every aspect of a project deadline. There are many factors that affect permit approvals. We are experienced in dealing with municipalities throughout the nation, so we are able to

What are the Precautions for the Start-Up and Use of Diesel Generator Sets?

  As a   Diesel Generator Manufacturer , share with you. Before starting the diesel generator set, we should first check whether all the switches and corresponding conditions of the generator set are ready, and start the engine set when the conditions are all feasible. Diesel Generator 1. The continuous working time of each start of the generator set should not exceed 10S, and the interval between two starts should be more than 2min to prevent the armature coil from overheating and burning out. If it fails to start successfully three times, you should find out the reason before starting. 2. When you hear the drive gear rotating at high speed and cannot mesh with the ring gear, you should quickly release the start button. After the starter stops working, start the second time to prevent the drive gear and the flywheel ring from colliding with each other and damage .  3. When using diesel generators to supply power in cold areas, switch to antifreeze oil; when starting, use a "one&q

STARLIGHT SILENT DIESEL GENSET

  STARLIGHT SILENT DIESEL GENSET Starlight silent diesel generator adopts vibration isolation, noise reduction, sound insulation, sound absorption, fireproof, high temperature resistance, rainproof, anticorrosion and so on noise reduction technical measures, which greatly reduces its noise index. This series of genset has remarkable low noise performance, multi-layer shielding impedance mismatch type soundproof cover, reducing the impact of noise on users. Starlight silent generator noise level can reach 75 dB, with low fuel consumption, reliable performance and easy operation features. Starlight silent gensets   are manufactured by adopting international advanced technology of generating sets. The gensets we manufactured comply with national standards GB/T2820-1997 or GB12786-91 and also have been put into the market. This series of gensets have significant low noise performace, multi-layer shieding impedance mismatch type acoustic shield, which greatly reduce the influence of noise o

New Genset 375KVA Diesel Generating Set with Yuchai Engine

Starlight Engineer Guides the User to Operate Ricardo Diesel Generator

24KW 30KVA WEICHAI DIESEL GENERATOR SET

  24KW 30KVA WEICHAI DIESEL GENERATOR SET Diesel Generator Set Data Set Type: XG-24GF Output Power: 24KW/30KVA Rated Current: 43.2 ( A ) Rated Frequency: 50 ( Hz ) Start-up time: 5 ~ 6 ( s ) Weichai Diesel Generator Set   Power Factor: 0.8 ( Lag ) Rated Voltage: 400/230 ( V ) Starlight Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realiz

New 500kva Diesel Generating Set with Yuchai Engine YC6T660L-D20

500KVA Shangchai Diesel Generator Set in Machine Room

450KVA 500KVA Diesel Generator Set with Cummins Engine KTA19-G3

Cummins 550kw Electric Generator for Sales-Starlight Power

75KW 93.75KVA PERKINS DIESEL GENERATOR SET

  75KW 93.75KVA PERKINS DIESEL GENERATOR SET Diesel Generator Set Data Set Type: XG-75GF Prime Power: 75KW/93.75KVA Rated Current: 135 (A) Rated Frequency: 50 (Hz) Start-up time: 5 ~ 6 (s) Power Factor: 0.8 (Lag) Perkins Diesel Generator Rated Voltage: 400/230 (V) Starlight Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system   for compact structure, advanced circuits, simple connections and high reliability Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto sta

Diesel Power Generators Manufacturer China

Ricardo diesel generator set for sale

68KW 85KVA VOLVO DIESEL GENERATOR SET

68KW 85KVA VOLVO DIESEL GENERATOR SET Diesel Generator Set Data Set Type: XG-68GF Prime Power: 68KW/85KVA Rated Current: 111(A) Rated Frequency: 50(Hz) Start-up time: 5 ~ 6(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Starlight   Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of 68kw Diesel Generator   automatic control system for compact structure, advanced circuits, simple connections and high reliability Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto start and stop of generators.

24KW 30KVA CUMMINS DIESEL GENERATOR SET

  24KW 30KVA CUMMINS DIESEL GENERATOR SET Diesel Generator Set Data Set Type: XG-24GF Output Power: 24KW/30KVA Rated Current: 43.2(A) Rated Frequency: 50(Hz) Start-up time: 5 ~ 6(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Starlight Electricity Equipments   Standard Features 1. Engine: DCEC Cummins 4B3.9-G2 2. Radiator 50 ℃ max 3. Fans are driven by belt, with safety guard 4. 24V charge alternator 5. Dry type air filter, fuel filter, oil filter 6. Alternator: single bearing alternator 7. IP23, insulation class H/H 8. Main line circuit breaker 9. Standard control panel 10. Absorber 11. Muffler 12. User manual Starlight   Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic

How to Maintain Fuel System of Electric Generators

Today Starlight silent diesel generators manufacturer shares fuel maintenance and fuel injector faults with you. Hope this article is helpful to you.   Fuel System The fuel system of the standard silent diesel generator includes: fuel tank, fuel supply pump, fuel filter, manual oil pump, fuel injection pump, fuel injection nozzle and related oil pipeline.   Only fuels that meet the quality specified in the following standards shall be used. It must be kept clean during refueling and fuel system operation. When working on the fuel system, it must be confirmed that the engine has cooled down. The splash of fuel on hot surface or electrical components may cause a fire.   Fuel specification The composition of the diesel oil has a very important effect on the operation and service life and the emission components of the diesel engine generator . In order to obtain the specified power, fuel economy and the emission standards specified by the local environmental protection department, only c