Skip to main content

Posts

Showing posts from July 14, 2019

Archive

Show more

1600kW Rated Power Cummins Diesel Generators with Marathon Alternator

Maintenance of Deutz Diesel Engine BF12M1015CP

6.1 Lubrication System 6.1.1 Oil Change Intervals - Deutz Diesel Engine The first oil change after commissioning or recommissioning following repair work is carried out after 50 running hours. The oil change intervals are depending on Lube oil quality and engine application. Should, within a year, the engine runs less than the hours stated in the table (250 h), the oil must be changed at least once a year. The table refers to the following conditions: - For diesel fuel max.sulfur content >0.5% by wt. - Continuous ambient temperature down to -10°C If the sulfur content is from 0.5% to 1%, or the continuous ambient temperature below -10°C, the intervals between the oil changes should be halved. In case of fuels containing sulfur >1%, ask your service representative. Note: Change the oil with the engine shutdown but still warm (lube oil temp.approx.80°C) 6.1.2 Check Oil Level/ Changing Engine Oil 6.1.2.1 Checking Oil Level Ensure that the engine o

500KW Cummins KTA19 G8 Water-cooled Diesel Power Generator

What are the requirements of the Cummins diesel generator set as an emergency (standby) power station

Cummins Diesel Generator Set is mainly used as Emergency (Standby) Power Station . The power supply system of emergency power station is generally not allowed to operate in parallel with the municipal power grid. Therefore, electrical and mechanical interlocking devices should be installed between the main circuit breaker of emergency generator set and the circuit breaker of municipal power supply to prevent misparallel connection between emergency power station and municipal power grid.Emergency units only automatically supply power to emergency loads (i.e. first-class engineering loads) when power failure occurs in the city. When the city's power grid fails and the emergency diesel generator starts up and runs, the emergency load should not be greater than the rated output capacity of the diesel generator set.The emergency load of the first batch of automatic operators should not exceed 70% of the rated capacity of generators, which is the secondary load originally

Starlight Power: professional supplier of diesel generator

What is Power Factor Lagging and Lead of Generator Set?

Due to some users ask Starlight Power manufacturer about lagging and lead of generator set question, today Starlight Power Manufacturer shares with you. What is generator power factor lagging? In alternator current, based on voltage, the phase angle of current lags behind the phase angle of voltage, which is called current lagging behind voltage. COSф of voltage and current lagging angle is power factor, because current lagging behind voltage is lagging power factor. Lagging of a generator is a common phenomenon, which indicates that the phase of current lags behind the phase of voltage, indicating that the circuit is inductive and the load of generator is the main type.   What is generator power factor lead? Only in circuits using capacitive elements, the current will exceed the voltage. Lead, is a rare case, indicating the current phase lead voltage phase, indicating that the line presents capacitance, load capacitance is too large,usually the capacitance compens

Heavy Duty 1200kw Yuchai Engine YC12VC2070 D31 Diesel Electric Generator...

Working Conditions of Weichai Diesel Engine for Power Generation

3.10 Power Definition and Working Conditions of Weichai Diesel Engine for Power Generation 3.10.1 Power definition Continuous Power COP In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under constant load.ISO standard power. Normal Power PRP In unlimited annual running time of diesel engine, the maximum power acquired when the engine is running continuously under variable load. ISO standard power which can overload by 10%. Standby Power ESP Maximum power in some variable power series with annual running time of diesel engine up to 200h.ISO standard power with limited fuel volume. 3.10.2 Running Conditions and Applications of Power Running conditions and applications of different powers of diesel engine are as shown in Table 3-1.   Ambiance condition The diesel engine should be able to output rated power in the following conditions. Atmospheric pressure, PX:100kPa (or 0 meter above sea level);

25kva-625kva Starlight Portable Trailer Diesel Generator Set