How To Choose A Generator Backup Power Supplier

Whether you want to install a backup generator to protect your home or business from downtime in the event of an emergency or need backup power generation, you need to make sure to buy your power from a reliable power supplier. Choosing the right supplier can make a big difference in quality, selection, and price. Next, Starlight Power lists the key factors to consider when comparing generator suppliers.   Select the backup power guide. While it may seem like you're getting a great deal, buying a   diesel generator   online is a risky move. Since anyone can post listings on these sites, it can be difficult to tell if a vendor is trustworthy. The following factors are critical in determining which backup power supplier to buy from:   Detailed Descriptions: A reputable supplier is sure to list detailed descriptions to make it easy for consumers to browse their inventory and get as much information as possible about each unit module. A good supplier will also include ph...

The Method to Install Oil Water Separator Of Diesel Generator Set

The oil-water separator for   diesel generator sets   uses the principle of oil-water density difference to make the oil float on the top, and the particulate matter and sludge settle at the bottom. It is regularly cleaned and eliminated by the submersible cutting pump installed in the sedimentation chamber, and there are also separation elements such as diffusion cone and filter screen inside. In order to allow the diesel generator set to use fuel safely and safely, the oil-water separator has been installed by the diesel generator set manufacturer before leaving the factory. The following are the replacement steps of the oil-water separator.   Install the oil-water separator of the diesel generator set and replace it as follows: 1. Open the water valve and let off part of the fuel.   2. Use a belt wrench to remove the filter element and the water storage cup together, and then remove the water storage cup from the filter element. Both the filter element and the wat...

The ways to reduce energy consumption in 450kw power generator

  Diesel generator set is widely used in industrial and agricultural production, national defense, science and technology and daily life. But many customers in the purchase of diesel generator set, in order to save cost, always want to buy the maximum power 300kw diesel generator with low cost. In the long-term operation process of diesel generator set, parts will produce certain loss. If it is light, it will affect the safe operation of the unit. If it is serious, it will lead to the normal operation of the unit.  So what kind of loss will 450kw diesel generator set produce in the process of operation?   1.When assembling 450kw diesel generator set, will install fan water radiator to connect alternator bearing. At this time, the power of the generator set will lose 10% compared with the diesel engine. 2.DC loss. It is the loss of generator stator current through stator winding. 3. Core loss, It is the magnetic loss produced by the generator flux in the generator. It incl...

Magnetizing Methods to Volvo Generators--Starlight Power

1.Use the starting battery (12V) of the diesel engine to power on the excitation wire (2 carbon brush wires) for a few seconds. It is better to magnetize it during operation. As soon as the battery contacts the excitation wire, the generator magnetizes and circulates to increase the magnetic field. 2.It should be noted that the time of grounding should not be too long, and that the speed of the diesel engine is slightly higher, it is better to carry a load, and connect an electric lamp, so as to know whether the magnetization is successful at any time. The reasons of no electricity in Volvo generators : 1.After shutdown, the remanence is often lost because the material used for the exciter pole is close to soft steel, and the remanence is small. When there is no current in the excitation winding after shutdown, the magnetic field disappears. 2.The pole of the generator loses magnetism. 3.The excitation circuit element is damaged or the circuit has open circuit,...

The Maintenance Ways for 500kw Volvo Diesel Generator

If we can inspect and maintain 500kw Volvo generator after it runs for a long time, we will reduce more unnecessary troubles. So, how we should inspect and maintain? Please follow us. 1.Primary technical maintenance: 50-80 hours.   (Added to the content of daily maintenance) A. Replace and clean air filter if necessary. The air filter is an unconspicuous but important part of the whole diesel generator set. Once the air filter is too dirty, it may cause serious mechanical accidents, especially in the environment and areas with poor air quality. In order to avoid shortening the service life of diesel generator, after shutdown, check the air filter in time and whether the air filter is blockage and damage. If so, clean and replace it in time. B. Check and replace the fuel filter and water filter; C. Check the tension of the drive belt; D. Add lubricating oil to all oil injection nozzles and lubricating parts; E. Replace cooling water. 2.Secondary technical main...

Volvo Diesel Generator Fails to Produce Specified Power

When Volvo diesel generator is failure to produce specified power, firstly we should check whether air intake and fuel injection are sufficient, whether the combustion process is normal and the compression pressure is large enough to analyze and judge step by step, find out the cause of the fault and eliminate it. The specific causes and solution methods are as follows: 1.Failure to produce specified power due to failure of valve mechanism and air inlet and exhaust system. Reason: Incorrect clearance between intake, exhaust valves and rocker arms; Incorrect actual opening and closing time of intake and exhaust valves; Valve spring is damaged; The valve has carbon deposits and the sealing surface leaks; Air filter blocked; Exhaust pipe and silencer have serious carbon deposits and poor exhaust. Treatment methods: Check and adjust to specified clearance; Check and adjust the opening and closing time of intake and exhaust valves; Replace new valve spring; ...