The Method to Install Oil Water Separator Of Diesel Generator Set

The oil-water separator for diesel generator sets uses the principle of oil-water density difference to make the oil float on the top, and the particulate matter and sludge settle at the bottom. It is regularly cleaned and eliminated by the submersible cutting pump installed in the sedimentation chamber, and there are also separation elements such as diffusion cone and filter screen inside. In order to allow the diesel generator set to use fuel safely and safely, the oil-water separator has been installed by the diesel generator set manufacturer before leaving the factory. The following are the replacement steps of the oil-water separator.

 

Install the oil-water separator of the diesel generator set and replace it as follows:

1. Open the water valve and let off part of the fuel.

 

2. Use a belt wrench to remove the filter element and the water storage cup together, and then remove the water storage cup from the filter element. Both the filter element and the water collecting cup are standard right-hand threads, so they can be removed in a counterclockwise direction.

 

3. Clean the water cup and oil ring. At this time, attention should be paid to the quality of the water cup and the oil ring. Generally, the quality of the diesel engine parts of the manufacturer has been tested.

 

4. Coat the oil ring with a thin layer of oil with grease or fuel oil, install a new filter element on the sump cup, and then tighten it by hand. Operators who have reached this step should pay attention. In order to avoid damage to the water storage cup and filter element, please do not use tools when tightening.

 

diesel generator set


5. Coat the oil ring on the top of the filter element with a thin layer of oil with grease or fuel, put the water cup and the filter element into the joint together, and tighten by hand.

 

6. In order to eliminate the air in the filter element, start the oil filling pump at the top of the filter to refuel until oil seeps out from the filter.

 

7. Start the diesel generator set to check whether there is leakage, if there is any, it can be stopped and eliminated.

 

The oil-water separator of the diesel generator set has been replaced at this step. If the replaced oil-water separator still fails to work properly, the operator should check the above steps step by step to check, if there are any errors in the above steps, or check out the Starlight Power website.

 

The above are the replacement steps of the diesel generator set oil-water separator introduced by Jiangsu Starlight Electricity Equipments Co.,Ltd. to the users.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a manufacturer of professional generators, diesel generator sets, Cummins generator sets, Volvo generator sets, etc. The company has advanced testing equipment, excellent production technology, professional manufacturing technology, perfect quality management system, and Strong R&D technical strength. It can provide 15KW-2500KW various specifications of universal, automatic, four protection, automatic switching, low noise and mobile, etc., high-quality, low-energy generating sets to meet customer power needs, and can also meet users' different voltages and different frequencies, as well as the power supply system of multiple units connected in parallel, welcome customers to inquire. For more details, please contact us with sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...