The Method to Install Oil Water Separator Of Diesel Generator Set

The oil-water separator for diesel generator sets uses the principle of oil-water density difference to make the oil float on the top, and the particulate matter and sludge settle at the bottom. It is regularly cleaned and eliminated by the submersible cutting pump installed in the sedimentation chamber, and there are also separation elements such as diffusion cone and filter screen inside. In order to allow the diesel generator set to use fuel safely and safely, the oil-water separator has been installed by the diesel generator set manufacturer before leaving the factory. The following are the replacement steps of the oil-water separator.

 

Install the oil-water separator of the diesel generator set and replace it as follows:

1. Open the water valve and let off part of the fuel.

 

2. Use a belt wrench to remove the filter element and the water storage cup together, and then remove the water storage cup from the filter element. Both the filter element and the water collecting cup are standard right-hand threads, so they can be removed in a counterclockwise direction.

 

3. Clean the water cup and oil ring. At this time, attention should be paid to the quality of the water cup and the oil ring. Generally, the quality of the diesel engine parts of the manufacturer has been tested.

 

4. Coat the oil ring with a thin layer of oil with grease or fuel oil, install a new filter element on the sump cup, and then tighten it by hand. Operators who have reached this step should pay attention. In order to avoid damage to the water storage cup and filter element, please do not use tools when tightening.

 

diesel generator set


5. Coat the oil ring on the top of the filter element with a thin layer of oil with grease or fuel, put the water cup and the filter element into the joint together, and tighten by hand.

 

6. In order to eliminate the air in the filter element, start the oil filling pump at the top of the filter to refuel until oil seeps out from the filter.

 

7. Start the diesel generator set to check whether there is leakage, if there is any, it can be stopped and eliminated.

 

The oil-water separator of the diesel generator set has been replaced at this step. If the replaced oil-water separator still fails to work properly, the operator should check the above steps step by step to check, if there are any errors in the above steps, or check out the Starlight Power website.

 

The above are the replacement steps of the diesel generator set oil-water separator introduced by Jiangsu Starlight Electricity Equipments Co.,Ltd. to the users.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a manufacturer of professional generators, diesel generator sets, Cummins generator sets, Volvo generator sets, etc. The company has advanced testing equipment, excellent production technology, professional manufacturing technology, perfect quality management system, and Strong R&D technical strength. It can provide 15KW-2500KW various specifications of universal, automatic, four protection, automatic switching, low noise and mobile, etc., high-quality, low-energy generating sets to meet customer power needs, and can also meet users' different voltages and different frequencies, as well as the power supply system of multiple units connected in parallel, welcome customers to inquire. For more details, please contact us with sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz