What to do if fuel mix with engine oil in diesel generator set?

The fuel oil and engine oil of diesel generator set have completely different functions. They can not be mixed. Once the fuel oil and engine oil are mixed, it means that the sealing of the unit is faulty, which happens sometimes in use. Today Starlight Power tell you how to deal with it. When fuel is mixed with engine oil in diesel generator set, it can be eliminated by the following methods: 1.   The oil transfer pump membrane is rotted or degummed, which makes the diesel oil flow into the oil pan and mix with the oil. Remove the oil transfer pump, and apply corresponding pressure to the oil inlet pipe and oil outlet pipe on the oil pump test bench. If no diesel leakage is found, the oil transfer pump is intact. 2.The fuel injector has low injection opening pressure and poor atomization, which makes the diesel flow into the oil pan along the cylinder wall and mix with the oil. Remove the injector and test it on the high-pressure oil pump test bench. If the opening pressure of the inje

1000KW Cummins Commercial Generator Set

The function of standby generators during power outage

Don't wait for the power failure to think of not buying a diesel generator as an emergency backup power supply. If so, you may have economic losses. Why is emergency standby diesel generator integral during power failure? Today Starlight Power manufacturer answers for you.   The phenomenon of power failure or high power loss caused by storms and other natural disasters is becoming more and more common. With the increasing dependence of internet technology on power, the reliability of power supply has become more and more important. For example, hospitals, data centers, water and sewage treatment facilities, gas stations, and communication and transportation systems need continuous power to ensure public health and safety.   Compared with other fuels and technologies,   diesel generators   can provide high quality and stable power supply and superior performance due to the transient or fluctuating power demand of high torque characteristics of diesel engines. Besides,

1000KW Cummins Commercial Generator Set

Why should you choose silent diesel generators

Why so many people prefer silent diesel generator set than open type generator? This article will share the reasons for high safety of   silent diesel generator set   by Starlight Power. 1. Loss of magnetic protection The loss-of-magnetization protection is used as the loss-of-magnetism fault protection for the generator excitation current to drop abnormally or disappear completely. It is composed of the excitation low voltage Ufd (P), system low voltage, static stability impedance, TV disconnection and other criteria that the setting value automatically changes with the active power, and acts on signalling and demagnetization. The excitation low voltage Ufd (P) criterion and static stability impedance criterion are both related to the static stability boundary. It can detect whether the generator loses static stability due to demagnetization. The static stability impedance criterion acts at the static stability boundary after demagnetization. 2. Overexcitation protection Ov

Grounding protection of diesel generators

Does diesel generator need to be grounded? The answer is Yes. Diesel generator must be grounded, because once the leakage of electricity occurs, it will produce a circuit with the earth, seriously affecting the safety of people.   The grounding protection of diesel generator is used in the ungrounded neutral system of three-phase power supply. Its function is that once the insulation of electrical equipment is damaged and leakage of electricity occurs, the human body contacts the charged shell. At this time, the human body resistance is far greater than the resistance of the grounding body (40). A large amount of current is discharged into the earth through the metal shell, and the voltage to the ground can be reduced to below the safe voltage of 36V.   If we adopt   grounding protection , when we touches the shell, due to the parallel connection between our body resistance and the grounding resistance, due to the human body resistance far greater than the grounding resi