The ways to reduce energy consumption in 450kw power generator

 

Diesel generator set is widely used in industrial and agricultural production, national defense, science and technology and daily life. But many customers in the purchase of diesel generator set, in order to save cost, always want to buy the maximum power 300kw diesel generator with low cost. In the long-term operation process of diesel generator set, parts will produce certain loss. If it is light, it will affect the safe operation of the unit. If it is serious, it will lead to the normal operation of the unit. 


So what kind of loss will 450kw diesel generator set produce in the process of operation?

 

1.When assembling 450kw diesel generator set, will install fan water radiator to connect alternator bearing. At this time, the power of the generator set will lose 10% compared with the diesel engine.


2.DC loss. It is the loss of generator stator current through stator winding.


3. Core loss, It is the magnetic loss produced by the generator flux in the generator. It includes three aspects: magnetic loss, eddy current loss and additional loss produced by the main flux in the stator core.


3.Excitation loss. It is the loss of excitation current in the rotor circuit when the generator is running.

 

4.Additional loss of electrical equipment, loss of leakage flux near the end of generator, loss of harmonic flux, iron loss of sub harmonic and high harmonic on the surface of rotor, etc.

 

5.Mechanical loss. It refers to the ventilation loss and friction loss of transmission parts during the operation of the generator set.


 Rainproof diesel generator


In order to prevent the wear of generator equipment and ensure the safe operation of the equipment, please focus on the regular maintenance of these parts, so as to improve the maintenance quality and extend the service life of the generator set.

 

According to your question, how to optimize the operation of diesel oil generator and reduce energy consumption? There are several ways to reduce energy consumption:

1.Pay attention to that some minerals or impurities, which will precipitate at the bottom of the purified diesel oil tank after it has been used for a period of time, which should be removed or purified regularly. Otherwise, it will have a great impact on the normal operation of the plunger and the fuel injection head, which is easy to cause inaccurate fuel supply time, uneven fuel supply, poor fuel atomization, etc., resulting in increased fuel consumption and decreased power.

 

2.During the operation of diesel engine, due to the high temperature of relevant components in the combustion process, the ash carbon polymer will adhere to the valve, valve seat, fuel injection nozzle, piston top, etc. if it is not cleaned in time, the fuel consumption will increase and the normal operation of the engine will be seriously affected. Generally, it is best to clean it once every 4-6 months.

 

3.Don't overload operation. The overload operation of small horse pulling cart type will turn a considerable part of diesel into black smoke, which will not give full play to its effective function, increase fuel consumption and shorten the service life of relevant parts.

 

Above information is about losses of in operation of diesel generator, hope it is helpful to you. If you are still not clear on this, do not hesitate to contact us. Besides, we also sell and produce diesel generator set with Cummins, Volvo, Perkins, Deutz, Yuchai, Shangchai generator, Weichai genset, Ricardo, MTU, Wuxi etc. Please send inquiry to us if you have plan to purchase, we will provide you the best product and service. Contact us: sales@dieselgeneratortech.com or call us +8613481024441.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...