What are the Precautions for the Start-Up and Use of Diesel Generator Sets?

 As a Diesel Generator Manufacturer, share with you.

Before starting the diesel generator set, we should first check whether all the switches and corresponding conditions of the generator set are ready, and start the engine set when the conditions are all feasible.

Diesel Generator

Diesel Generator

1. The continuous working time of each start of the generator set should not exceed 10S, and the interval between two starts should be more than 2min to prevent the armature coil from overheating and burning out. If it fails to start successfully three times, you should find out the reason before starting.

2. When you hear the drive gear rotating at high speed and cannot mesh with the ring gear, you should quickly release the start button. After the starter stops working, start the second time to prevent the drive gear and the flywheel ring from colliding with each other and damage . 

3. When using diesel generators to supply power in cold areas, switch to antifreeze oil; when starting, use a "one" screwdriver to pull the flywheel ring gear at the flywheel inspection hole for a few weeks before starting.

4. After the unit is started, the start button should be released quickly to return the drive gear to its original position.

5. During normal operation of the unit, it is strictly forbidden to press the diesel engine start button again.

6. Grease should be added to the bushings of the front and rear cover regularly to prevent dry friction from damaging the shaft and bushings.

Our company also has Diesel Generator on sale, welcome to contact us.


Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...