Skip to main content

Archive

Show more

How to Choose Air Filter for Diesel Generator



Air Filter

The dust in the air is the primary reason on abrasion for cylinder liner, piston, piston ring, valves, valve stem guide and other athletic parts, the more the dust in the intake to the engine is the more the abrasion of the engines parts is. It is founded by wearing test of engine that the dust less than a diameter 0.001 mm has an very small effect on engines, the dust with a diameter between 0.001 mm and 0.01 mm has measured effect on the engine if the diameter of the dust in the intake is larger than the thickness of the bearing oil film, it will affect the life of the main and connecting bearing and the piston ring. Therefore, to extend the service life of a diesel generator, it is very important that air filter should be chosen carefully.






According to different uses, air filter is divided into normal duty and heavy duty air filters. The minimum efficiency for normal duty cleaner at any flow between 15% and 100% at the rated air flow is 99.5%; and its minimum dust holding capability is 3.0 gram/CFM( or 6A gram/L.S) at rated air flow, it will be applied primarily to those generator drive engines and marine engines.

The minimum efficiency for heavy duty filter at any flow between 15% and 100% of the rated air flow is 99.9% and its minimum dust holding capability is 25.0 gram/CFW (or 53 gram/L.S) at rated air flow, it will be applied primarily to the mining product, construction product, automotive product, off-high heavy duty, etc. Those engines ( and generator drive engine) and marine engines ( and generator drives engines).



After the air cleaners have been used for period of time, its elements will be dirtied, and restriction of the air intake will increase. When the restriction increases to above 6.25kPa, the engine can not get sufficient air. Therefore, the engine will discharge the black smoke and the engines power will be own.

The customer can estimate the air-logged conditions of the air filter by the air induction indicator or annunciator, if the indicating window of the indicator changes from green to red, or the annunciator gives an alarm, the air intake restriction had exceeded the limit valve, and the element will need to be cleaned up or replaced.

The following methods can be used to clean up the element of the air filter:

a. Lightly knock the end plate & the element to shake off the dust accumulating on the element;
b; Open the dust discharging jaws on the air cleaner to remove the dust in the air cleaner shell.
c. Open the end cover of the cleaner and pull out the element.
d. Clean up the element with the dry compressed air.

Note:

a. It is not permitted to clean up the element with oil or water.
b. For the heavy duty air filter, there are many convolute pipes, these pipes can not be taken down, and it can be washed up with hot alkaline water, flush it with cleanly water, then blow it with compressed air.
c. The secondary ( or safety) element of the heavy duty air cleaner  can not be cleaned up.

When the following problems are founded, the primary element must be replaced with a new element.

a. The primary element is in disrepair.
b. After assembly the element, the indicator indicates red or the annunciator for gives an alarm again.

c. The primary element have boon cleaned up for five times.
Note: For heavy duty air filter, when its primary element is disrepair or cleaned up for five times, its secondary must be replaced.




Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...