Skip to main content

Archive

Show more

Terminal Pillars Letters Meaning in Deutz Generator Set


In generally, there is terminal pillars in generator, such as armature, magnetic field, tower, neutral point, etc. These terminal pillars have different letters, what does the letters mean? Today Starlight manufacturer talks about terminal pillars letters meaning in Deutz generator set.
1. Armature terminal pillars. It is a coarser terminal pillars in generator, in generally, its diameter is 6mm;
2. Magnetic field terminal pillars and neutral point terminal pillars. There are two buttons on the generator, usually 3 mm in diameter. One of the screw roots contacts directly with the outside or connects with conductive copper sheet, which is a tower terminal pillars. Another adjacent thin terminal is the magnetic field terminal, and an independent terminal is the neutral point terminal;
3. Use multimeter to measure and identify. Before measure, remove the wires on the terminal pillars of the generator, place the multimeter in RX10 gear and RX100 gear, then one watch rod is connected to the generator housing, and the other one is connected to two thin terminal pillars on the brush rack. If the resistance value is 0, that is tower terminal pillars, if there is resistance value, that is magnetic field terminal pillars.

The rectifier end of the generator has different terminals and different alphabetical symbols on the corresponding positions. The meaning is as follows:
1. “A”, “B+” or “B” ( Battery) is armature terminal pillars, which connecting with positive rectifier board inside the generator and output electric energy outward. Connect with positive battery and starter through thicker conductor. Generally power output line also known as “B”.
2. “F” ( Field) is magnetic field terminal pillars, which applied to generator. It connects to the one end of inside generator and excitation winding, and connects to the "F" terminal of the voltage regulator. For an integrated generator (built-in integrated circuit voltage regulator), the end of the excitation winding connected to the integrated circuit regulator is also called "F".
3. “N” or “P” is neutral point terminal pillars, which connecting to the star type neutral point inside the generator. Generally used to control relays for various purposes, such as charging indicator relay, magnetic field relay, etc. For the integrated generator (built-in circuit regulator), the neutral point (or the contact point in three-phase winding) is generally connected with the integrated circuit regulator.
4. “L” (Light) is charging indicator terminal. Inward, connected with integrated circuit voltage regulator, through the voltage regulator to control the operation of charging indicator; outward, generally connected to charging indicator through the burning switch.

5. “E” ( Earth) is a common sign of the earth terminal pillars. Generally it is connected to generator casing. Inward, connect to “E” or “-” letter terminal pillars on voltage regulator, the purpose is to let the generator and voltage regulator form a good circuit to ensure the normal operation of the charging system.
6. “IG” (Ignition) is Ignition terminal pillars, generally control the operation of generator though it. Outward connect to positive electrode of battery through ignition switch.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...