Skip to main content

Archive

Show more

Volvo Generator Introduction--Volvo Diesel Engine


Volvo Generator Introduction--Volvo Diesel Engine


Starlight Volvo series diesel generator is powered by renowned electric-fuel-injection diesel engine, comply with EURO II or EURO III and EPA standard for exhaust emission. The global-famous Swedish VOLVO was establish in 1927. its strong brands have long been linked with its three core values: quality, safety and care of the environment. Volvo Penta, one of the subordinates of VOLVO group is expert at production of power generating engine, vechicle engine, and marine engine. The technologies of six-cylinder and electronic injection outdisance other competitors, enjoying advantages as small volume, fuel-saving, high precision, long operating life. The high-quality products have won favorable comments from customers home and abroad.


Volvo Generator Advantages


Volvo generator engines adopt full electronic fuel injection control technology, with high performance and high reliability. They have the merits of good startup performance, voltage stability, reliable operation, low emissions, low noise, convenient maintenance, good efficiency and good ability to adapt the plateau.Starlight Volvo series diesel gensets officially authorized products of the Volvo company. With better performance, better quality and more guaranteed services compared with similar products, they are products recommended by the Starlight Volvo Genset Department.



Introduction of Volvo company


Volvo company is Sweden's largest industrial enterpriseswith a history of 120 years, and it is one of the world's oldest engine manufacturers.So far its engine production has reached more than 1 million sets, and they have been widely applied in power section of automobile, engineering machinery and ships. They are even the ideal for power gensets.VOLVO company, at the same time, is the only manufacturer in the world to focus on inline four-cylinder and six-cylinder diesel engines, and it is in a leading position on this technology. VOLVO generator series are imported with original packaging, with a full set of certificate of origin, certificate of approval, inspection certificate, customs declaration certificate, etc. As VOLVOs OEM partner, our company has provided hundreds of high-performance gensets for domestic users.



Characteristics of Volvo Diesel Engines
1. High ability to withstand the load and fast, reliable cold start performance, low resistance supercharger and responsive injection system lead to a high resistance to load of the engine in a very short recovering time;

2. The heater is installed in the intake manifold, making it easier for the engine to start at a low temperature.

3. Stable working, low noise, optimized design of damping body, accurate matching of turbocharger amd low-speed cooling fan. Less emissions, low operating cost, typical exhaust smoke less than 1 Bosch units;

4. Low fuel consumption

5. Small and exquisite: delicate and exquisite appearance design compared with other products.

6. Real international applicable parts with global recognition and global service network. Sweden Volvo have set up large center for maintenance, training and spare parts distribution in China.



Characteristics of Volvo Diesel Generator Sets
1. Power range:68KW550KW

2. Strong ability to withstand load

3. Smooth operation and low noise of Engine

4. Fast and reliable coldstart performance

5. Delicate and exquisite appearance design

6. Small fuel consumption, low operating cost

7. Less emissions, economic and environmental protection

8. Service network all over the world, plenty of spare parts supply



Volvo Generator Supply Standard Configuration


1. Warranty card of original factory for Diesel engine (with all accessories, three-filters, electrical system),

2. Manual of brushless AC generator

3. Steel structure base Engine operation manual

4. Fan radiator cooling system Generator operation manual

5. Flange connecting shaft Test report of sets

6, 24V start motor and charging motor Diesel gensets

7. Air filter, diesel filter, oil filter Product certificate

8. Airborne type control panel

9. MCCB air protection switch

10. 24v start-up battery and battery line

11. Shock absorber of sets

12. Efficient industrial muffler

13. Random technical documents



Installation of Volvo Generators
1. Choice of Volvo generator chamber
1) Volvo diesel gensets require that surrounding environment is conducive to the ventilation and exhaust

2) Enough operation space

3) Reasonable layout

4) Cannot place flammable items



2. Installation basis of Volvo gensets
1) As long as the ground has enough bearing capacity, the foundation platform is not needed

2) Volvo diesel gensets adopt effective shock absorbing device, and foundation need no isolation treatment

3) For the size of the foundation platform, please refer to the "Installation Manual"

4) No anchor bolt should be reserved for the foundation platform



3. Cooling and ventilation system of Volvo gensets
1) Standard Volvo diesel gensets use the closed cooling water cycle system

2) Due to chamber conditions, we may adopt fission type cooling system or heat exchanger system

3) Air inlet and outlet should be in reasonable layout, avoiding heating reflux

4) Air inlet and outlet should be meet the minimum clearance requirements



4. Fuel supply system of Volvo gensets
1) GF series Volvo diesel gensets need to be equipped with daily tank additionally

2) The height difference between the tank and the unit meets the requirements

3) The oil taking and returning pipe should meet the size requirement

4) The oil supply system is installed in line with the fire code

5) When the fuel is in poor quality, the installation of a oil-water separator is recommended



5. Exhaust system of Volvo diesel gensets
1) Volvo diesel gensets are equipped with an industrial muffler according to the standard

2) The exhaust system should reduce the quantity of elbow and shorten the total length of the exhaust pipe as far as possible

3) When the length and the quantity of elbow is beyond standard, we should make an appropriate increase in the exhaust pipe diameter

4) The bellows shall be installed between the exhaust pipes and the sets for the purpose of isolation






Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

Function Of Battery, Breather And Radiator In Diesel Generator

A diesel generator is a diesel powered machine capable of converting mechanical energy to electrical energy. It basically consists of a diesel engine, who's drive shaft is directly connected to something called an alternator. The job of the alternator is to convert the mechanical energy provided to it by the diesel engine to electrical energy. So the alternator consists of 2 windings called the stator winding and the rotor winding. During operation the stator winding is stationary while the rotor winding are performing circular motion (since they are connected to the drive shaft of the diesel engine). Working Of The Alternator: The rotor windings are excited by some DC current so that a magnetic field is produced around the coil. Since it is performing circular motion the magnetic flux linked with it also keeps performing circular motion at the same speed. This magnetic flux is intersected by the stator winding which is fitted around the rotor. According to Faraday...