Learn about the Function of Diesel Generator Air Filter




An air filter is an important part of a car's intake system, because it is what allows the car to "breathe." An engine needs an exact mixture of fuel and air in order to run, and all of the air enters the system first through the air filter. This catches the dirt and other foreign particles in the air, preventing them from entering the system and possibly damaging the engine.

This article is mainly written to introduce the diesel generator filter types as well as its function. If you are interested, then read on.

In general, filter is divided into three types, namely, oil filter, fuel filter and air filter. For different types, the function is also different.

Oil Filter - It is used to remove dust in the engine oil, metal particles. carbon deposits and sooty particles and other impurities so as to protect engine.

Usually, oil filter is divided into full flow type and shunt type. The full flow filter is connected between the oil pump and the main oil gallery in series, hence, it can filter all lubricating oil entering the main oil gallery. However, the shunt filter is connected with the main oil gallery in parallel, only can filter part of the lubricating oil.

Fuel Filter - The main function of any diesel fuel filter is to remove foreign particles as well as water so as to protect fuel pump, nozzle, cylinder liner, and piston ring, etc, and to reduce wear and avoid clogging.

After learning about the two filters mentioned above, now let me introduce another filter to you Air Filter

How does generator air filter work?

It is mainly used to filter the particulates and impurities in the air so as to reduce the  wear of the piston rod, valve gear and the cylinder. Usually, the air filter consists of two parts: filter element and shell.
In general, there are two types of air filters, dry type and wet type.
A dry type air filter is a filter that separates the impurities from the air through a dry type filter element.
However, a wet type air filter includes oil-immersed and oil-bath two types.
The main function of the oil-immersed type filter is to separate the impurities from the air through the filter element.
The main function of the oil-bath type filter is to import the dusty air into the oil tank to remove most dust.

Usually, air filtration has three ways, inertia, filter and oil-bath way.

Inertia type: Because the density of the particles and impurities is greater than the density of the air, when the particles and impurities rotate with the air or take a sudden turn, the particles can be separated from the air flow under the action of centrifugal inertial force.

Filter type: Guide the air to flow through the metal screen or filter paper, so as to block the particles and impurities and make them paste on the filter element.

Oil bath type: Equipped with oil pan at the bottom of the air filter, using the air flow to impact the oil to separate the particles and impurities and make them stick in the oil; the oil droplets flow through the filter core with air and adhere to the filter core.Air flows through the filter element, which can adsorb impurities further, so as to achieve the purpose of filtering.

Genset air filter replacement cycle: replace the filter when the common generator sets work every 500 hours; replace it when the standby generator sets work for 300 hours or half year. In addition, the genset maintenance is also very important and necessary, which contribute to extend the replacement cycle.

In general, the maintenance period of the diesel generator air filter is conducted every 50 hours.

If the filter is not too dirty, it can be directly blown with compressed air, but it should be noted that the air pressure cant be too big, besides, the nozzle cant be too close to the filter element. However, if the filter is too dirty, you should use special cleaning fluid to clean it, and then blow it to dry. After the cleaning is completed, check the air filter, use the light to lighting from inside and outside, observe at the external of the filter, if found there is a light-spot, it shows that the filter has been perforated, you should replace the same type of the filter. If there isnt a light-spot, it shows that the filter hasnt been perforated. You should be careful to install the air filter.

We supply multiple brands of generator set, such as: Cummins, Volvo, Deutz, Doosan Daewoo, MTU, Ricardo, Perkins, Shangchai, Weichai, Yuchai etc. The style of genset is varied, such as: container genset, trailer genset, portable trailer genset, soundproof genset, low noise genset, and silent genset, etc. Besides, we also supply design and construction of the noise reduction project up to the customer's requirements.

Cellphone: +86 134 8102 4441
sherly@dieselgeneratortech.com

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...