How To Test The Lubricating Oil For Engine


The most important requirement of a lubricant is to form a film between the moving parts to keep the surfaces separate under all loads and temperatures. The viscosity of the oil can be influenced with additives to have a viscosity that is high enough to form the protective film but low enough not to cause excessive energy losses within the film.



Nowadays, fuel economy is becoming more and more important and the viscosity of the oils is getting lower and lower. It is of great importance that the viscosity remains stable during the whole oil drain interval.
Innovation in Viscosity Determination: SVMStabinger ViscometerSeries

The highly precise viscometers of the SVMseries are based on a rotational measuring principle and have an integrated density measuring cell. The small viscosity measuring cell contains a tube which rotates at a constant speed and is filled with sample fluid. A measuring rotor with a built-in magnet floats freely in the sample. The samples shear forces drive the rotor while magnetic effects retard its rotation. Shortly after the measurement starts, the rotor reaches equilibrium speed. This speed is a measure of the fluids viscosity.

As the density cell of SVMis integrated, the density measurement does not have to be carried out separately. In fact, one combined measuring cell covers the entire measuring range for viscosity, density, and temperature and is filled in one go. A minimum sample amount of only 1.5 mL is sufficient for multiparameter results in one fast measurement.

Top Benefits for Lubricating Oil Testing
Measuring Range

In virtually every lab, from time to time a sample outside the usualviscosity range needs to be measured. This often poses a problem with traditional measuring methods and is time-consuming to perform. With SVM3001, one combined measuring cell covers the entire measuring range for viscosity, density, and temperature and is filled in one go. The viscosity measuring range of the cell is from 0.2 mm²/s to 30 000 mm²/s, whereby the temperature range is from -60 °C to +135 °C (-20 °C is reached without external cooling). This measuring range allows for measuring a wide range of samples of different viscosity with one integrated measuring cell and, combined with very fast heating and cooling rates as well as the powerful temperature scans, this opens new possibilities in lubricating oil testing.

Fast Heating/Cooling Rates

With traditional bath systems for temperature control, the user normally needs to choose the measuring temperature and never change this temperature 24/7 until the next scheduled maintenance. In contrast, SVM3001 has very fast heating/cooling rates of up to 20 °C/min. Such fast temperature changes allow for extraordinary flexibility when choosing the samples, measuring temperatures, and tests that need to be performed. Paired up with the wide temperature range of SVM3001 from -60 °C to +135 °C and the possibility to perform fast and easy temperature scans, it is possible to obtain valuable information on the viscosity behavior of the lubricating oils. Together with the small sample volume of just 1.5 mL (for both viscosity and density determination) not only temperature changes but also thermal uniformity is rapidly achieved. The direct thermo-electric cooling by Peltier elements provides very sensitive and fast control of the cell temperature. So, after entering a new set temperature, it takes only a few minutes for the instrument to be ready for the next test.

With built-in air cooling, SVM3001 can reach -20 °C without the need for any thermal transfer liquids or external devices.

The True Value of Temperature Scans

As fuel economy and long drain intervals are the most important requirements for trucks and buses, when developing engines the analysis of the oil is very important. One of the most important parameters is the viscosity of the oil at different temperatures. Therefore, a temperature scan is very helpful for the construction engineers to do calculations of the bearings in order to ensure that enough protective film is available.

After one injection of the sample via syringe, SVM3001 can run a temperature table scan from -20 °C to +130 °C in 10 °C steps. Since SVM3001 does not need any external cooling to reach -20 °C, the entire measurement is done with one stand-alone instrument in a simple manner. All data are available about 1h 25 min after the start of the scan and no operator attendance is needed in the meantime. Measurement values for kinematic viscosity are obtained, but also for dynamic viscosity and for density all in one graph (Figures 1 and 2).

Figure 1. Temperature scan graph

Figure 2. Table temperature scan

Integrated Density Measurement

Due to the density oscillator integrated in SVM, the density measurement according to ASTM D4052 or ISO 12185 is carried out simultaneously with the viscosity measurement. In other words, the density thermal coefficient of the current sample is a measured value instead of the typical value for the product group. This offers various possibilities and hence flexibility. Since density at 15 °C or 20 °C is commonly needed, a temperature table scan can be set up with the required temperatures (e.g. 15 °C, 40 °C, 100 °C) as shown in Fig. 3. Another possibility would be API calculations of density over temperature, which are integrated in the instrument software and are freely selectable on the 10.4touchscreen.

Figure 3. Kinematic viscosity, density, and VI values of
various operating fluids

Viscosity Index Reloaded

In the automatic Viscosity Index mode, temperature changes are performed automatically and the Viscosity Index is calculated in compliance with ASTM D2270. Typically, the measurements are performed at 40 °C and 100 °C, but since viscosity-temperature extrapolations according to ASTM D341 are integrated in the instrument software, the measurements can also be performed at two different temperatures and the Viscosity Index automatically calculated. The benefit of this measurement is that the actual density of the lubricating oil at both temperatures is also measured. This means that the extrapolation of the density from these two points (lying far apart) is precise. It is sometimes also referred to as a density-temperature slope. For the lubricating oils tested, the extrapolations error was found to be lower than 0.0001 g/cm3.

Low Sample Volume Importance in Real Life

The viscosity is also important for used oils. Change in viscosity can reveal oil thinning due to fuel dilution or oil aging. For example, in contrast to conventional diesel, bio-diesel does not evaporate out of the engine oil and this leads to a continuous thinning, which in turn requires more frequent oil change.

In such cases of oil samples from the field, often only low sample volume is available, but a number of different tests need to be performed in the laboratory. In such cases, the low sample volume required for a multiparameter determination with SVMis very beneficial. The minimum sample volume required for SVM3001 is only 1.5 mL; typical sample volume amounts to approximately 5 mL. Also, with the small cell of the new SVMthe cleaning requires low solvent amounts, which means a fraction of waste liquid of that with traditional methods ensuring reduction of solvent disposal costs.



Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...