Advantage of Cummins Genset




Advantage of Cummins Genset


Starlight Cummins series diesel generatorsets are officially authorized products of the Cummins company. With better performance, better quality and more guaranteed services compared with similar products, they are products recommended by the Cummins Genset Department.

Brief introduction of Cummins company


Cummins is in the world largest company today in design, production and sales of diesel engine and compressed natural gas engines.Cummins has invested more than one hundred and forty million dollars in China, covering Dongfeng Cummins Diesel Genset and Chongqing Cummins Diesel Genset.Cummins own eight joint ventures and sole-funded manufacturing enterprises in China. Dongfeng Cummins produce B, C and L series diesel engines, and chongqing Cummins produce M, N and K series diesel engines.Products comply with ISO 3046, ISO 4001, ISO, IEC 34-1, 8525 GB1105, GB/T 2820, CSH 22 0530-2, VDE and YD/T 502-502 "Special Technical Requirements of Diesel Gensets Only for Communication Purposes" and other standards.

Advantages of Cummins generators/gensets:
They have a good quality, low fuel consumption, low noise, big output power and reliable performance. Their reliable stability, economy, power performance, durability and environmental safety is welcomed by customers at home and abroad, and they offer a warranty of the global Three Gurantee. The engines of the Sino-US joint venture Dongfeng Cummins and Chongqing Cummins have small volume, light weight, low fuel consumption, high power and reliable work, and the spare parts supply and maintenance is convenient. They adopt electronic governor, with protection functions such as alarm and automatic parking for too high temperature in the cooling water, too low oil pressure or too high speed.



Product overview of Cummins generators/gensets


1) Design, production and testing of the gensets are in full compliance with national standard GB/T2820-97.

2) Equipped with Cummins engine. With advanced technology, reliable performance and long service life.

3) the excitation systems of generators enable the quick recovery of frequency fluctuation in any instantaneous loading.

4) Low power design of the generators minimizes the waveform distortion under nonlinear loads, and brings a good ability of starting motor.

5) Cummins compnay provide quality assurance for all series products of the company.

6) Cummins has built a professional service network all over the country, which provides after-sales services and supply spare parts for 24 hours a day.



Process introduction of Cummins generators/gensets:


1. Air intake and exhaust system of Cummins gensets

1) Use the hanger or brace to support the exhaust pipe and the supercharger

2) Bellows are strictly prohibited to act as elbow and the compensation of installation error

3) For sets over 200 kw, stainless steel bellows above 610 mm are used.

4) Gas pipes are in horizontal layout with a slope of 0.3-0.5%. The slope face the outdoor, and a drain valve is set at the lowest position.

5) The diameter short not be less than vent pipe during the configuration of engine exhaust pipe.

6) If the exhaust pipe must be bending upwards, the drainage bolt should be set up at the starting point of going up.

7) During the installation of multiple gensets, special attention should be paid to common exhaust pipes.


2. Cooling systems of Cummins generators

1) Air inlet should be set on the ends or both sides of generators, with the area 2.2 times greater than the tank area.

2) The air outlet area should be 1.5 times of water tank area, and the shutters and wind wall should be installed at the air outlets.

3) flexible duct flanges are used to connect to the water tank, so as to absorb displacement and vibration of the sets and prevent the spread of noise.

4) Hot air must be vented to the outside of the chanber through the air duct, and the duct area should be smoothly transitted from small to large values. If thereare curves in the air ducts, the guide plate must be installed in order to reduce the pressure loss.

5) when the environment temperature is higher than the design temperature, we should consider use it by redcuing the power.


3. Standard configuration of Cummins generators/genset

Engine: Cummins 4 stroke diesel engines

Generator: Stanford/marathon brushless AC generators

Control system: controllers dedicated for the sets with the microprocessor acting as the core

Start-up system: the engine adopts DC motor startup

Short circuit protection:MCCB air switch

Cooling system: online cooling tank that could satisfy the requirement of ambient temperature at 40oC

Filter system: Cummins engine oil, fuel oil and air filter

Attachment: accessories such as exhaust elbow, bellows, silencer

Installation of Cummins generators/generator
1. Chamber design of Cummins generator

1) The sets should be in horizontal layout, and they can be in longitudinal layout when they are limited by the building site.

2) When the chamber is adjacent to the control chamber, the outlet end of the generator and the cable trench should be close to the transformer chamber.

3) The battery should be close to the side of the start-up motor

4) The chamber should have enough inlets for fresh air. The duct of the hot air and smoke should be stretched out to the outdoor, air inlet should be placed by the side of the motor, and theair outlet should be installed in the side of the tank.

5) The chamber should adopt comprehensive control measures for the noise removal of sets and sound insulation of chambers.



2. Processing method in noise reduction of Cummins gensets

A. Gensets are installed on the concrete floor.

1) We should pour a reinforced concrete base over the floor.


2) The concrete base should pass one month pressure test of over 173 kpa.


3) The concrete base should be at least 150 mm above the floor, with an extension of at least 150 mm per side laong the chassis of the set,


4) The cement base should be embedded with the "J" or "L" type anchor bolt.


B. Gensets are fixed on the chassis type fuel tank:


1) The shock absorber must be equipped between engine and fuel tank.


2) The structure and strength of the tank must be able to support static load and dynamic load of the sets.


3) We must keep a certain distance between the bottom of the tank and the ground, so as to facilitate the maintenance.




Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...