Low Voltage of Diesel Generator



Low voltage of diesel generator will affect the use of generator set, which is one of the common faults. This article will guide you to learn the factors that affect the voltage of generating set.

1. The unstable speed of the engine causes the unstable voltage of the generator set.

2. If the load on the generator set is too large, the voltage will be unstable.

3. The damage of the voltage regulator components of the generator causes the units voltage instability.

4. The poor circulation of the fuel pipe of the genset causes the unstable speed of the engine, which causes voltage instability.

We recommend you to use the following methods to check and handle the low voltage fault of diesel generator sets.

1. If the contact surface of generator brush is too small and the voltage caused by poor contact is too low, it is necessary to check whether it is caused by the commutator surface, if it is, at low speed, to polish the commutator surface with sand cloth, or to adjust the spring pressure.

 2. When the generator set is used, the voltage is too low. It may also be that the diesel generator speed is too low. In this case, you need to check the diesel engine speed. You only need to adjust the prime mover speed to the rated value.

3. During the process of using diesel generator set, the unit voltage is too low because the resistance of the excitation circuit is too large, and the resistance of the magnetic field rheostat is reduced to increase the excitation current. For semiconductor excitation generator, check if the additional winding connector is broken or connected incorrectly.

4, check whether the generator exciter brush is in the neutral line position. It is recommended to adjust the electric brush to the correct position, or to replace the brush to solve the problem of low voltage.

5. Check if there is a short circuit or ground fault in the stator winding or excitation winding of the generator set, and check the fault and clear faults in time.

6. Some rectifier diodes are broken down. It is necessary to deal with in time. Check and replace the broken diodes.

Starlight Power company mainly produces diesel generator set and has 43 years experience in power generating sets manufacturing. Main products include Volvo generator, Cummins generator, Perkins generator, Ricardo generator, and Yuchai diesel generator and so on. All our products are approved by CE/ISO. Gensets meet international applicable standard ISO 8528. According to customersrequirements, we also provide installation, commissioning, training, and maintenance service.



Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...