Cooling Tests for Volvo Diesel Engine


Cooling Tests for Volvo Diesel Engine


Cooling Tests, General
Glossary

A number of terms are used to define cooling system capacity. Maximum ambient temperature. The maximum ambient temperature the machine may be used in without exceeding the permissible water temperature.

Δt water (delta t) - the temperature differential between radiator inlet and outlet

coolant.

Δt air - the temperature differential between radiator inlet and outlet air.

Cooling capacity

A cooling system installation's cooling capacity is often measured using a reference temperature for coolant boiling point called ATB (Air To Boil). The ATB temperature is defined as the ambient temperature at which the coolant attains its maximum permissible coolant temperature. AOT (Air On Temperature) refers to the maximum permissible coolant temperature after the Volvo engine of diesel generator set. It is defined as the temperature of the cooling air entering the charge air cooler. The difference between AOT and ATB temperatures is that the input cooling air temperature is used instead of the ambient temperature.

The maximum permissible temperatures for each engine type are given in Technical data, in Sales Support Tool, Partner Network This concerns unpressurized cooling systems. If the system is fitted with a pressure cap or pressure valve the boiling point will rise according to the pressure setting value.

Cooling Test Preparation

Before the application is prepared for a cooling test it is extremely important to ensure that the installation in general is satisfactory. If any adjustments are necessary as a consequence of the tests, and which may affect cooling in particular, such changes must be made at this stage. It is also extremely important to have accurate and reliable instruments available, as well as other equipment and aids recommended for performing the cooling tests. Sometimes all the recommended equipment may not be available, but remember that the main objective is to ensure that the application is tested under a load cycle that corresponds to the most difficult conditions the application can be exposed to during use.

If there is any uncertainty about how difficult the conditions the application will be exposed to will be, we recommend always to attempt maximum output at rated rpm. Measuring instruments must be installed at the recommended locations. All tests must be performed with a fixed open thermostat. A short test run must be made to check that all parts with temperature probes attached are functioning correctly. The test must be carried out in dry conditions with a wind speed that does not exceed 7 m/s (23 ft./s) and preferably with an ambient temperature above +5 °C (+41 °F). Before the cooling test is carried out, exhaust back pressure must be determined at rated rpm under full load.

Air filter resistance must be determined with the engine at maximum rated rpm and load. Regardless of the type of application being tested, the maximum load condition expected during application use must be determined. One practical method of determining maximum load conditions is to check exhaust gas temperature. When the maximum load condition has been determined, the application must be run continually at this load until temperatures have stabilized. This usually takes 50 to 60 minutes. The installation checks must be concluded with a technical report that includes all test results, a detailed description of the genset installation and a conclusion.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz