Guides to Reduce the Wear of Diesel Generator Parts



While the diesel generator is running the load, it is also the process of mutual wear of the parts of the diesel generator itself. Starlight Power Diesel Generator Manufacturer recommends that users minimize the wear between the components of the gensets. Reducing the wear of the parts is also a way to extend the service life of the unit. Here are some effective ways to reduce wear of the generator parts.







The quality of the fuel and lubricant of the diesel generator set should be matched with corresponding specification of generating set.



If diesel contains sulphur or other impurities, acid and other corrosive substances will be generated during the combustion process to accelerate the wear of the cylinder; too much heavy fraction in the diesel fuel will easily form carbon deposits after combustion, abrasive wear is generated between the piston ring and the cylinder; viscosity of the diesel has an effect on the formation of the mixture and the reliability of the oil supply equipment. For lubricating oil, the viscosity and oxidation resistance is the most influential. It should be reasonably selected according to the working conditions of the diesel generator set.



Tests showed that the friction of diesel generators increases with the increasing of rotating speed and load. As the load increases, the unit pressure on the friction surface increases and the thermal condition is poor. When the rotational speed increases, the number of times of frictions is increased by half per unit time, and under the same power, the increase of rotational speed is greater than the load increases.



However, too low rotating speed can not guarantee good liquid lubrication conditions, and also increases wear. Therefore, a suitable working speed range is required for the trouble-free operation of power generator.



In addition, when the operation of diesel generator set is often unstable, such as acceleration, deceleration, stop and start, due to frequent changes in the speed and load, the lubrication condition of diesel genset is poor, the thermal state is unstable, and the wear is increased.



Especially when starting, the crankshaft speed is low, the oil supply from oil pump is not in time, the oil temperature is low, the oil viscosity is large, and the friction surface is difficult to establish liquid lubrication, and the wear is very serious.



Diesel generator set wear caused by ambient temperature



Engine is easy to overheat when the temperature is high, the viscosity of the lubricating oil is low, and the wear of the parts is increased. When the temperature is low, the viscosity of the lubricating oil becomes large, and the diesel generator is difficult to start. The cooling water cannot maintain the normal temperature during operation, which increases the wear and corrosion of the parts. The wear is more serious when the gensets is at low temperature.



The operating temperature of diesel generating set is one of the important factors affecting the wear. During the process of operating, due to the limitations of the cooling system structure, change in the workload and speed and the change in the ambient temperature, the operating temperature of the diesel generator set varies greatly. Practice shows that the cooling water temperature is controlled at 75-85°C, and the lubricating oil temperature is 75-95°C.



To sum up, users should strengthen the technical study of diesel gensets to ensure the correct use of the units and reduce the wear of parts. The engineer of diesel generator manufacturer instructs everyone to proceed from the following aspects:



1. Reasonable choose the operating condition of the diesel generator.

2. Improve the running-in quality of diesel generators.

3. Select fuels and lubricants suitable for the working needs of diesel engines.

Select suitable lubricant and lubrication method, replace dry friction with ideal fluid friction, which is the most effective way to reduce friction and wear. For generators, according to the specific requirements of different engine and the season and the use of different regions to choose the appropriate brand of lubricants.

4. Improve the level of operation technology and timely maintenance.

During use, the maintenance of the fuel supply system, the intake system and the lubrication system should be done.



No matter how good the quality of the product, only know how to better maintain, can reduce the wear of the products and extend the service life of the machine.


Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz