How the Fuel Regulating System of Diesel Generator Set Works



How the Fuel Regulating System of Diesel Generator Set Works


The fuel speed control system is the main component of the diesel engine. It consists of oil pump, fuel filter, fuel injection pump, governor, fuel injector, high pressure oil pipe oil return pipe.

The oil pump sucks the fuel from the fuel tank and sends it to the fuel filter. After filtering, it enters the fuel injection pump. After the fuel pressure of the fuel injection pump is increased, the fuel supply amount required by the same working condition is sent to the high pressure oil pipe. The injector is finally sprayed into the combustion chamber through the nozzle of the injector. In order to maintain the appearance and surrounding fuel cleaning of the diesel engine, a small amount of fuel flowing out of the fuel return pipe from the side of the injector should be returned to the fuel tank by the user.


The reliability of the operation of the fuel speed control system directly affects the performance of the diesel engine. Therefore, whether it is in operation, disassembly and repair, installation or in test adjustment, the most important thing is to keep it clean. This is the first condition for ensuring quality.



The governor used in the Randy series diesel engine is divided into two types, one is the electronic governor, which includes the following parts:



(a) speed sensor

(b) electromagnetic actuator

(c) speed thrower, and control and switches, connecting cables and other accessories.



The rotational speed sensor is installed above the flywheel housing of the diesel engine, the rotational speed signal is transmitted from the diesel flywheel ring gear, and the electromagnetic actuator is installed at the rear end of the high pressure oil pump. The speed controller and the connecting cable are placed or installed in the diesel monitor box by the user. Its high and low speed conversion, parking switch (power switch) is available at random. The power supply of the electronic governor, which can significantly improve the speed regulation performance of the diesel engine. Its steady state speed regulation is not more than 3%, and the speed fluctuation value is small, which can fully meet the technical requirements of the power station.



When the diesel engine was tested in the factory, the parameters of the speed controller of the electronic speed control system were correctly adjusted, and the low speed setting and high speed setting were painted and sealed, and the user could not adjust it arbitrarily.



If the user needs emergency stop due to special circumstances, the diesel engine equipped with electronic governor can turn off the power switch of the electronic governor (that is, the parking switch of the diesel engine) to cut off the power supply of the electronic governor and achieve emergency stop. The mechanical centrifugal full program has high-speed limit screws on the operating mechanism. The diesel engine has been adjusted and sealed before leaving the factory. The user can unpack it without the permission of the factory professional, otherwise the product will not be listed into the product  quality three packs of service. A parking handle is also installed on the front of the governor for emergency parking. A low-speed stabilizer is also installed on the governor housing to prevent low-speed instability of the diesel engine. When the diesel engine is stable at low speed, the low speed stabilizer can be slowly screwed in until the speed is stable (the normal speed fluctuation is within the range of ±25/min) and then fixed. All factory diesel engines have been adjusted, and users should not pull them when necessary. If the fuel pump and governor are disassembled and repaired, and the diesel engine is unstable, the user can adjust it by himself. However, it must be noted that the low speed stabilizer can not be screwed in too much, so as to avoid excessive speed of the empty car and cause an accident.



The steel plate coupling is connected between the high pressure oil pump and the drive shaft of the lattice series coupling is connected between the high pressure oil pump and the drive shaft of the transmission system.



In order to ensure the reliable operation of the steel plate coupling and avoid the steel plate breakage accident in the device caused by the installation and use, the user should pay special attention to the following items when changing or adjusting the steel plate coupling parts.



First, the steel plate coupling is placed on the drive shaft of the fuel injection pump, so that the shaft can be axially moved, then the bolt D (2 pieces) is loosened, and the rear end of the steel plate glaze is bolted A (2 pieces) Tightening on the diesel fuel injection pump disc, the final tightening torque of bolt A is 40N 'm, and then tighten the bolt D (2 pieces) on the steel plate coupling. The tightening torque of bolt D is 40N 'm, then adjust the steel. The axial position of the plate coupling ensures that the steel sheet must not be flexed, and then tighten the bolt B (1 piece) with a tightening torque of 40N. m50N. m, the steel plate coupling and the fuel injection pump drive shaft are reliably tightened, and finally the bolt C (2 pieces) is loosened, the diesel fuel supply advance angle is adjusted within the specified range, and the bolt C (2 pieces) is tightened to 40N. 'm, the installation work of the steel plate coupling is completed.



Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...