Skip to main content

Archive

Show more

Noise Reduction Principle of Diesel Generator Silencer


The noise reduction of diesel generator sets needs to deal with the causes of the above noise respectively. The main methods are as follows.

1. Air intake and exhaust noise reduction: the intake and exhaust air channels in the engine room are used as soundproof walls, and the silencers are set up in the inlet and exhaust air channels. There is a distance buffer in the channel, which can reduce the intensity of the sound source radiation from the engine room.

2. Control of mechanical noise: the top and surrounding walls of the machine room are covered with high absorption and sound insulation materials, which are mainly used to eliminate indoor reverberation and to reduce the sound energy density and reflection intensity in the machine room. In order to prevent the noise from radiating through the gate, fire-proof iron door is set.

3. Control smoke noise: the smoke exhaust system installed on the basis of the original primary silencer special two-stage silencer can ensure the effective control of the smoke noise of the unit. Exhaust pipe length more than 10 meters to increase the diameter of the exhaust to reduce the generator set back pressure. The above treatment can improve the noise and back pressure of the generator set. Through the noise reduction, the noise of the generator set in the engine room can meet the requirements of the users outside.




The silencer of diesel generator machine is developed according to the principle of anti-noise, anti-injection and compound anti-noise. It has the advantages of large volume, small volume, light weight, stainless steel manufacture, easy corrosion and convenient installation. The sound wave is attenuated by expanding cavity and perforated plate, and the sound becomes heat energy. The principle of which is mostly multistage throttling and lowering pressure, high pressure steam passing through a control flow in the muffler and entering the pressure relief body after a large volume diffuser. In this process, the internal energy of the airflow is partially converted into sound energy of a certain frequency, and its noise is greatly reduced. In a ejected and mixed silencing shell, 2-4 energy dissipation and sound suppression inner tanks are arranged centrally. In order to absorb the thermal expansion of the exhaust steam pipe, a double-layer acoustic mask was designed in the depressurized body to move vertically and horizontally between the inner gallbladder shells to absorb the thermal expansion of the exhaust steam pipe.

Muffler is a kind of device that prevents sound from propagating and allows airflow to pass through. It is an important measure to eliminate the dynamic noise of steam emission. To measure the quality of exhaust muffler, the following three aspects are considered:

1. The muffler's noise quantity can meet the requirement of "hygienic Standard of noise in Industrial Enterprises"

2. Adaptive performance of muffler (I. E. wide band of low and medium frequency spectrum, high temperature and high pressure, etc.)

3. Structure and performance of muffler. (reasonable size, low cost, long life, etc.)

The exhaust muffler of diesel engine is suitable for noise attenuation on the exhaust pipe of diesel generator, and also for other exhaust systems containing a certain amount of smoke and dust.

The noise reduction principle of diesel generator muffler is as follows.

The exhaust muffler of diesel generator is mainly analyzed from three aspects: noise attenuation performance aerodynamic performance and structure performance. It should have the characteristics of higher noise attenuation wider frequency band smaller resistance loss and simple structure. The exhaust muffler of diesel generator engine is usually designed as microperforated plate impedance compound type. It has high noise suppression capacity in low, medium and high frequency, and can withstand high temperature and air impact, low resistance loss and low regenerative noise. The silencing amount can reach 20dB (A). The structure of microperforated plate impedance compound muffler is commonly used.

The theory and calculation methods of the muffler, especially the microperforated tube section, are not perfect, so the performance of the muffler can be evaluated only after the experimental measurement. The expansion ratio m (m=D2/d2) of Beijing diesel generator muffler has a great relationship with the noise attenuation, so the reasonable choice in design should be between 4 ~ 15 and 4 ~ 15. In a certain range, the larger m is, the better the silencing effect is, but m can not be too large. Otherwise, the section of the expansion chamber is too large, so that the medium and high frequency sound wave does not propagate in the form of plane wave in the muffler, but the beam wave passes through it, which leads to the decrease of the silencing volume. In the low frequency range, when the wavelength is much larger than the size of the expansion chamber, because the expansion chamber itself is equivalent to a low pass filter, it will affect the effective low frequency muffler range of the diesel generator muffler. The sound absorption coefficient and band width of perforated plate are mainly determined by perforation rate and aperture. The aperture of microperforated plate is in the range of 0.5~1mm, the perforation rate is 1 / 3% and the thickness is generally between 0.5~1mm. In order to achieve wide band and high frequency absorption, the perforation rate of the front layer near the air flow is sometimes slightly higher than that of the rear layer, and the depth of the front and rear cavity may be the same or different, but before, the ratio of the rear cavity depth should not be greater than 1: 3.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...