Skip to main content

Archive

Show more

Starlight fights against novel coronavirus together with all people

To ensure the continuous and stable use of electricity in hospitals is the most important task in the fight against the new coronavirus pneumonia epidemic situation.

In order to ensure the safe and reliable power supply of Guangxi version "Xiaotangshan Hospital" -- Nanning Yongwu hospital, people's Hospital Branch of Guangxi Zhuang Autonomous Region, at 7 a.m. on February 4, 2020, our company successfully delivered an 800kw container generator set to the site.

800kw container generator set

The purchaser is Guangxi Nanning Power Supply Bureau of China Power Grid Co., Ltd. In view of the current needs of epidemic prevention and control, Nanning city plans to add emergency medical facilities in Yongwu branch of district hospital. In order to ensure medical power consumption, the Bureau has transferred a large number of materials for power supply construction. In order to ensure the completion of the project in early February and improve the epidemic prevention and control facilities in Nanning, the hospital needs our company to send an 800 kW container type diesel generator set to Yongwu hospital in XiXiangTang District, Nanning.

After receiving the notice on February 1, 2020, in the first time Starlight company transported the units that meet its requirements from Jiangsu headquarters for emergency dispatch day after day on February 2, and successfully arrived at the construction site on February 4, and officially put into use after debugging on February 7.

 800kw container generator set

"Only when the electricity is guaranteed can the medical staff work normally and orderly." Mr. Cheng Xingrong, the star of starlight, was escorting the crew. He was a veteran. He sacrificed the precious time of Spring Festival and family reunion   to actively respond to the needs of users and the national government. He went out overnight to provide strong support for the timely delivery of the generator set!

"In order to deal with sudden power failure, remember that the generator must be started once every day, running without load for about 15 minutes, to ensure that the generator can work normally at all times." Mr.Gu said, the after-sales service center of Starlight Company, repeatedly told the user about the precautions for using the unit.

 800kw container generator set

In order to win the sniper battle of epidemic prevention and control, the power supply guarantee of hospital is very important. During the fight against novel coronavirus, starlight service staff will follow up the maintenance and technical support of diesel generator sets to ensure that the epidemic prevention and control institutions need to meet the demand for emergency electricity, and to light confidence with love and warmth.

Starlight has focused on high quality diesel generators for more than 43 years since 1974. Product covers Cummins, Volvo, Perkins, Deutz, Yuchai, Shangchai, Ricardo, Weichai etc. Power range is from 25kva to 3000kva. More details, please contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...