Skip to main content

Archive

Show more

Water-cooled Open Type Diesel Generator Set Shanghai 150kw



We are Jiangsu Starlight Electricity Equipments Co.,Ltd., a manufacturer of diesel generator set in China since 1974. We are authorized as the OEM supplier of Shangchai diesel engine of generator set. Today we share 150kw Shangchai diesel generator set technical specifications.
1. 150kw Shangchai diesel generator set technical specifications
Prime power/capacity: 150kw/187.5kva
Standby power/capacity: 165kw/206kva
Speed/frequency: 1500rpm/50Hz
Voltage: 230/400V
Start up time: 5~6s
Noise level: open type: 100dBA at 7 meters, soundproof type: 75dBA at 7 meters.
Voltage Regulation: ≥±5%
Sudden Voltage Warp (100% Sudden Reduce):≤+25%
Sudden Voltage Warp (Sudden Increase):≤-20%
Voltage Stable Time (100% Sudden Reduce): ≤6s
Voltage Stable Time (Sudden Increase):≤6s
Frequency Recovery Time(100%Sudden Reduce):≤6s
Frequency Regulation:≤5%
Voltage Stable Time (100% Sudden Reduce):≤5s

2. Shangchai diesel engine SC7H250D2 for 150kw generator set
Prime power: 168kw
Standby power: 185kw
The engine performance is as per GB/T2820.
Ratings are based on GB/T1147.1.
Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating.
Standby power is available in the event of a utility power outage or under test conditions for up to 200 hours of operation per year.
The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating.
3. SPECIFICATIONS
Engine Model: SC7H250D2
Engine Type: In-line,4 strokes, water-cooled ,4 valves, Turbo charged & air-to-air intercooled.
Combustion type: Direct injection  
Cylinder Type: Dry liner
Number of cylinders: 6
Bore × stroke 105(4.14) × 124(4.89) mm(in.)
Displacement: 6.44(393) lit.(in3)
Compression ratio: 16 : 1
Firing order 1-5-3-6-2-4
Injection timing 12°BTDC
Injection pump Longkou in-line “P” type
Dry weight Approx. 580 kg (1278.7 lb)
Dimension(L×W×H): 1343×741×1267 mm (52.9×29.2×49.9 in.)
FUEL CONSUMPTION
Power                         L/h
110%                          40.5
100%                         36.5
75%                         27.3
50%                         18.2
25%                          9.6

LUBRICATION SYSTEM
Lub. Method Fully forced pressure feed type
Oil pump: Gear type driven by crankshaft
Oil filter: Full flow, cartridge type
Oil pan capacity: High level 17.5 liters ( 4.62 gal.) Low level 15 liters ( 3.96 gal.)
Lub. Oil: Refer to Operation Manual
COOLING SYSTEM
Cooling method: Fresh water forced circulation
Water capacity: 9.6 liters (2.5 gal.) (engine only)
Pressure system: Max. 0.5 kg/cm2 ( 7.11 psi)
Water pump: Centrifugal type driven by belt
Water pump: Capacity 170liters ( 44.9 gal.)/min at at 1,500 rpm (engine)
Thermostat:Wax–pellet type, Opening temp. 82°C, Full open temp. 95°C
Cooling fan: Blower type, plastic 660 mm diameter, 10 blades
ELECTRICAL SYSTEM
Charging generator 28V×55A
Voltage regulator Built-in type
Starting motor 24V×6kW
Battery Voltage 24V  
Battery Capacity 150 AH
FUEL SYSTEM
Injection pump: Longkou in-line “P” type
Governor:Electric type
Feed pump: Mechanical type
Injection nozzle: Multi hole type
Opening pressure: 250 kg/cm2 (3556 psi)
Fuel filter: Full flow, cartridge type
Used fuel Diesel fuel oil

Above is some part of Shanghai engine SC7H250D2 for 150kw genset technical specification. If you are interested in Shanghai generator set, please contact us by sherly@dieselgeneratortech.com. Shanghai genset power is from 55kw-880kw, you can choose power capacity according to your need, and alternator we have Stamford, Leroy Somer, Marathon, Siemens, Engga, Shanghai Kepu, as well as our own brand Starlight( full copper wire).

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz