High Quality 580kw/725kva Cummins Diesel Generator Set

580kw/725kva Cummins diesel generator is supplied by Starlight Power factory, having open type, silent container type, trailer type. Here is the technical specifications for your reference before you purchase.

1.Cummins diesel generator data

Prime power: 580KW

Standby power: 639KW

Engine model: KTA38-GA

Alternator: Stamford HCI634G1

Controller: Deep Sea DSE7320

Rated voltage: 400/230V( or as you need)

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

3 phase & 4 wire

Fuel consumption @ 1500rpm: 133L/h (100% prime rated load)

Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd.

2.Cummins genset diesel engine KTA38-GA data

Manufacturer: Chongqing Cummins Engine Co.,Ltd.

Model: KTA38-GA

Prime power:647KW

Standby power:711KW

Speed: 1500rpm

Displacement38L

Bore X Stroke159X159mm

Compress Ratio:14.5:1

Aspiration: Turbocharged

Fuel System: Cummins PT

No. of CylinderV-12

Governor type: electronic

EXHAUST SYSTEM

Maximum Allowable Back Pressure (1500rpm): 2.3in.Hg(3kPa)

Maximum Allowable Back Pressure:3in.Hg(10kPa)

Exhaust Pipe Size Normally Acceptable:6in(152mm)

COOLING SYSTEM

Coolant Capacity

With heat exchanger HX 4073 ( With out explantion tank):18U.S.Gal(66L)

With explantion tank & LTA: 30U.S.Gal(112L)

Maximum Coolant Friction Heat External to Engine @1500 rpm:7PSI(48.3kPa)

Minimum Raw Water Flow @ 90°F(32℃) to Heat Exchanger With HX 4073:54GPM(204.4L/min)

Standard Thermostat (modulating) Range:180-200°F(82-99℃)

Maximum Allowable Coolant Temperature :205°F(96.1℃)

LUBRICATION SYSTEM

Oil Pressure

@ Idle:20PSI(138kPa)

@ Rated Speed:45-65PSI(310-448kPa)

Maximum Allowable Oil Temperature:250°F(121℃)

Total System Capacity (Excluding By-Pass Filter):45U.S.Gal(170L)

FUEL SYSTEM

Fuel Injection System: Cummins PT direct injection

Battery Recharge System,Negative ground:35A

Maximum allowable resistance of starting circuit:0.002Ω

3.Stamford alternator HCI634G1 data

Brand/Model: Stamford/HCI634G1

Manufacturer: Cummins Generator Technologies(China) Co.,Ltd.

Frequency: 50Hz

Protection level: IP23

Insulation: H

Voltage regulation: AVR

Capacity: 725KVA

Overload: 10% overload for one hour per 12 hours

Bearing: Single bearing( without PMG or with PMG, as you need)

4.Controller Deep Sea DSE7320

Model: DSE7320

Manufacturer: UK Deep Sea

Starlight Power factory has focused on high diesel generator set for more than 43 years since 1974. Our genset with Cummins engine is the best sales and popular with good performance, low fuel consumption and competitive price. If you want to order, please call us +8613481024441.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...