Skip to main content

Archive

Show more

1000kva power diesel generator sets in China

On 28 June, 2020, Shengbang Group bought diesel generator set with Starlight Power company again. This time they purchased open type Shangchai 800kw generator set used for real estate project as emergency standby power supply.

 

This is the eighth cooperation with Starlight Power company. Since April 2015, Shengbang Group has total bought 8 sets diesel generators from Starlight Power company:

2020.05: Shangchai 720kw generator set

2019.01: Shangchai 630kw generator set

2018.07: Shangchai 400kw generator set

2016~2015: 2 sets Shangchai 800kw generator set


Shengbgang Group has a long term cooperation with Starlight Power, because of good quality product and after-sales service. Starlight power generator guarantees the smooth progress and completion of customer projects. Thanks for Shengbang Group’ cooperation again. For every client, we shall continue to strive for a better product and service.

 

Technical data of 800kw diesel generator set

Prime power: 800kw/1000kva

Standby power: 880kw/1100kva

Diesel engine: Shangchai SC33W1150D2

(Turbocharged, water-cooled, 6 cylinders, bore x stroke: 180x215mm)

Alternator: Shanghai Kepu TFW2-800

Controller: SmartGen HGM6110N

1500rpm, 50Hz, 230/400V, 3 Phase 4 Wire, P.F.0.8

Genset size: 4850x1850x2200mm

Net weight: 6500kg


 Shangchai genset in machine room


As emergency standby diesel generators, when the power grid is cut off or reasons are interrupted, it is set up to ensure the basic production ans life of the users. This kind of generator set is located in the industrial and mining enterprises, hospitals, hotels, banks, airports, radio stations and other important power consumption units.

 

Emergency generator sets are often set up to supply emergency power to the electrical equipment which will cause heavy losses or personal accidents, such as fire control system of high-rise buildings, evacuation lighting, elevator, control system of automatic production line and important communication system. This kind of generator set needs to be installed with self starting function, which requires high degree of automation.

 

Starlight Power generator set is automatic start and stop type. It has automatic transfer function. When power grid off, the genset can auto start, auto change over power switch, auto stop etc. When oil pressure is too low, oil temperature too high or water temperature too high, the genset can auto indicate the alarm information. When over speed, can auto stop for protection. There are also other functions and performance.

 

Of course, Starlight Power also has prime diesel generator set. This kind of generator sets operate all year round, and are generally located in areas far away from the power grid (or called municipal power) or near industrial and mining enterprises, so as to meet the needs of construction, production and living in these places. At present, in areas with rapid emergency development, it is necessary to build prime diesel generator sets with short cycle to meet the needs of users. The capacity of this kind of generating set is generally large.

 

Starlight Power company can make a suitable generator set according to clients’ requirements, if you have purchase plan, welcome to contact us by our sales person email sales@dieselgeneratortech.com or WeChat +8613481024441.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...