500kw 625kva Cummins silent diesel generators exported to Saudi Arabia

Recently, Starlight Power exported one unit 500KW Cummins silent containerized diesel generator set to Saudi Arabia, the customer has received it. It is our honor to cooperate with the customer, thanks for the cooperation!

 

This 500KW diesel generator set is configured as follows:

Diesel engine: Cummins KTAA19-G6A

Manufacturer: Chongqing Cummins Engine Company Ltd.

Type: 4 stroke, in line, turbocharged & air to air intercooled

Displacement: 19L

BoreXStroke: 159X159mm

Compress Ratio: 13.9:1

No. of Cylinder: 6

Fuel System: Cummins PT

Frequency/speed: 60Hz/1800rpm

Standard: BS-5514 and DIN-6271 standards are based on ISO-3046.


500kw Cummins generator set  

               

Alternator: Shanghai Kepu TFW2-500-4A

Manufacturer: Shanghai Kepu Generator Equipment Co., Ltd

Alternator capacity: 625KVA

Protection level: IP22

Insulation class: H

Efficiency: above 95%

Bearing: Single bearing

Type: Brushless and self-exciting

Voltage regulation: AVR

 

Controller: SmartGen 6110

Manufacturer: SmartGen(Zhengzhou) Technology Co., Ltd.

 

1.jpg


Performance characteristics of Starlight silent containerzied diesel generator set

1.The noise reduction standard conforms to ISO standard.

2.Good ventilation system and thermal radiation prevention measures ensure that the unit always works at the appropriate ambient temperature.

3.Super large capacity fuel tank for 8 hours of continuous load operation

4.The use of special noise reducing and silencing materials can greatly suppress the mechanical noise.

5.Efficient damping measures to ensure stable operation of diesel generator set.

6.Special observation window and emergency stop button are set at the appropriate position of silencing shell to facilitate operation and observation of unit operation.

7.Rain proof and silent set for outdoor use.

 

Soundproof box structure

1.Corrosion protection

Box made of cold rolled steel plate;

Steel door locks, hinges and fasteners;

Zinc phosphate and polyester powder coating treatment, durable appearance as new.

 

2.Good maintenance contact

Large size door, air resistance rod;

Panel lamp and maintenance lamp;

The oil pipeline leads to the outside of the compartment.

 

3.Superior security

The built-in muffler independent of the equipment makes the operation safer and the appearance more beautiful;

The sound insulation observation window is easy to observe the operation condition of generator set outside the chamber;

External emergency stop button;

High efficiency, flame retardant and sound-absorbing materials are pasted inside the compartment.

 

4.Convenient transportation

Skeleton structure, modular design;

High strength sound box chassis;

The upper part of the silent compartment is provided with lifting ears.


5.Good acoustic effect

The noise level of generator set is 75dBA at 7m.

 

Thanks to the customer's recognition of our products, Starlight will continue to provide customers with quality-assured diesel generator sets. If you are interested in our Cummins generator set, contact us by email: sales@dieselgeneratortech.com

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz