Skip to main content

Archive

Show more

500kw 625kva Cummins silent diesel generators exported to Saudi Arabia

Recently, Starlight Power exported one unit 500KW Cummins silent containerized diesel generator set to Saudi Arabia, the customer has received it. It is our honor to cooperate with the customer, thanks for the cooperation!

 

This 500KW diesel generator set is configured as follows:

Diesel engine: Cummins KTAA19-G6A

Manufacturer: Chongqing Cummins Engine Company Ltd.

Type: 4 stroke, in line, turbocharged & air to air intercooled

Displacement: 19L

BoreXStroke: 159X159mm

Compress Ratio: 13.9:1

No. of Cylinder: 6

Fuel System: Cummins PT

Frequency/speed: 60Hz/1800rpm

Standard: BS-5514 and DIN-6271 standards are based on ISO-3046.


500kw Cummins generator set  

               

Alternator: Shanghai Kepu TFW2-500-4A

Manufacturer: Shanghai Kepu Generator Equipment Co., Ltd

Alternator capacity: 625KVA

Protection level: IP22

Insulation class: H

Efficiency: above 95%

Bearing: Single bearing

Type: Brushless and self-exciting

Voltage regulation: AVR

 

Controller: SmartGen 6110

Manufacturer: SmartGen(Zhengzhou) Technology Co., Ltd.

 

1.jpg


Performance characteristics of Starlight silent containerzied diesel generator set

1.The noise reduction standard conforms to ISO standard.

2.Good ventilation system and thermal radiation prevention measures ensure that the unit always works at the appropriate ambient temperature.

3.Super large capacity fuel tank for 8 hours of continuous load operation

4.The use of special noise reducing and silencing materials can greatly suppress the mechanical noise.

5.Efficient damping measures to ensure stable operation of diesel generator set.

6.Special observation window and emergency stop button are set at the appropriate position of silencing shell to facilitate operation and observation of unit operation.

7.Rain proof and silent set for outdoor use.

 

Soundproof box structure

1.Corrosion protection

Box made of cold rolled steel plate;

Steel door locks, hinges and fasteners;

Zinc phosphate and polyester powder coating treatment, durable appearance as new.

 

2.Good maintenance contact

Large size door, air resistance rod;

Panel lamp and maintenance lamp;

The oil pipeline leads to the outside of the compartment.

 

3.Superior security

The built-in muffler independent of the equipment makes the operation safer and the appearance more beautiful;

The sound insulation observation window is easy to observe the operation condition of generator set outside the chamber;

External emergency stop button;

High efficiency, flame retardant and sound-absorbing materials are pasted inside the compartment.

 

4.Convenient transportation

Skeleton structure, modular design;

High strength sound box chassis;

The upper part of the silent compartment is provided with lifting ears.


5.Good acoustic effect

The noise level of generator set is 75dBA at 7m.

 

Thanks to the customer's recognition of our products, Starlight will continue to provide customers with quality-assured diesel generator sets. If you are interested in our Cummins generator set, contact us by email: sales@dieselgeneratortech.com

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...