How to maintain Cummins diesel generators in coolant?

 

Diesel generator is affected by its own diesel combustion during operation, which will lead to sudden rise of diesel engine temperature. In high temperature environment, it will not only affect the improvement of working efficiency of diesel generator, but also cause the occurrence of parts failure. Based on this, we need to cool the heating part, which involves the problem of adding coolant to the diesel engine cooling system. What is the effect of the coolant on the operation of diesel generator set?

 

1.Antifreeze

Under the condition of low temperature, the cooling system of diesel engine is not damaged. Generally speaking, the freezing resistance temperature of common coolant is that the freezing point is between 20 ℃ and 45 degrees below zero, and it is reasonable to choose according to the actual needs of different regions.

 

2.Anti boiling effect

Under high temperature, it is ensured that there will be no premature boiling. The boiling point of common coolant is 104 degrees to 108 degrees. When the coolant is added to the cooling system and the pressure is generated, the boiling point will be higher.


3.Antiseptic effect

Special coolant can reduce the corrosion of cooling system, thus avoiding the water leakage caused by corrosion of cooling system.


 500kw Cummins generator


4.Rust prevention

High quality coolant can avoid the rust of cooling system, once the cooling system rust will lead to accelerated wear and reduce the heat conduction efficiency.

 

5.Antiscaling

Because the coolant is deionized water, it can avoid scaling and precipitation and protect the engine.

 

How to maintain Cummins diesel generators in coolant?

1.Heating water in winter

In cold winter, the engine is difficult to start. If cold water is filled before starting, it is easy to freeze in the water tank water chamber and water inlet pipe, which makes the water unable to cycle or even make the water tank crack. Hot water can be added to improve the engine temperature for easy start-up; on the other hand, the above freezing phenomenon can be avoided as far as possible.


2.Antifreeze should be of high quality

If there is no preservative in the antifreeze, it will seriously corrode the engine cylinder head, water jacket, radiator, water stop ring, rubber parts and other components, and produce a lot of scale, which will lead to poor heat dissipation and overheating of the engine. Therefore, we must choose the products of regular manufacturers.


3.Replenish soft water in time

After filling antifreeze in the water tank, if it is found that the liquid level of the water tank decreases, on the premise of ensuring no leakage, only clean soft water (distilled water is better), because the boiling point of ethylene glycol antifreeze is high, and the evaporation is the water in the antifreeze. It is not necessary to add antifreeze, but only soft water. It is worth mentioning: never add hard water without softening.


Silent electric generator


4.Discharge antifreeze in time to reduce corrosion

Whether it is ordinary antifreeze or long-term antifreeze, when the temperature becomes higher, it should be released in time, so as to prevent the corrosion of parts. Because the preservatives added in the antifreeze will gradually reduce or fail with the extension of service time, what's more, some simply do not add preservatives, which will have a strong corrosive effect on the parts. Therefore, the antifreeze should be discharged in time according to the temperature, and the cooling pipeline should be thoroughly cleaned after the antifreeze is discharged.

 

5.Open the water tank cover when discharging coolant

If the cover of the water tank is not opened, part of the cooling water can flow out, but with the decrease of the water volume in the radiator, a certain degree of vacuum will be generated due to the sealing of the water tank, and the water flow will slow down or stop. In winter, the parts will be frozen due to unclean water discharge.

 

6.It is not advisable to discharge coolant immediately at high temperature

Before the engine stalls, if the engine temperature is very high, do not stop immediately to drain water. The load should be removed first to idle the engine. When the water temperature drops to 40-50 ℃, the water will be drained to prevent the temperature of the cylinder block, cylinder head and water jacket in contact with water from dropping suddenly due to sudden water discharge, and the temperature inside the cylinder block is still very high and the shrinkage is small. It is easy to make it easy to make it because of the excessive temperature difference between the inside and outside cracks are found in cylinder block and cylinder head.

 

7.Idle the engine after draining coolant in cold winter

In the cold winter, the engine should be started to idle for a few minutes after the cooling water in the engine is discharged. This is mainly because some water may remain in the water pump and other parts after the water is discharged. After the engine is started again, the residual water in the water pump and other parts can be dried by the body temperature, so as to ensure that there is no water in the engine and prevent the phenomenon of water leakage caused by the freezing of the water pump and the tearing of the water seal.


Above information is about coolant of Cummins diesel generators. When you doing maintenance, you can refer to the article, but should be done a professional person in order to ensure safety. Starlight Power also provide 20kw-2000kw Cummins diesel genset, now we have promotion activity, if you have purchase plan, please contact us for more details.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...