Skip to main content

Archive

Show more

Features of DEUTZ Diesel Generator Set





1. Products have compact structures, reasonable design, excellent and reliable performance, long service life and low usage cost.
2. From the view of product structures, the generators have three product platforms: C, E, D products,with the power range covering 85~340 horsepower.There are more than 300 kinds of products with various forms and adaptability, and these can provide power products with higher technology level and stronger specialization degree for those fields with different demands, such as medium-duty trucks, light vehicles, buses and engineering machiner.
3. Generator products have a series of significant advantages such as advance, efficiency, readability, energy saving and environmental protection.
4. With functions of backflow, well adapt to the plateau and high altitude regions.
5. Starlight series DEUTZ Gensets are the officially authorized products of DEUTZ company. With better performance, better quality and more guaranteed services compared with similar products, they are products recommended by the Diesel Genset Department.

Product overview of DEUTZ gensets
1, DEUTZ engine have advanced technology, reasonable design, excellent and reliable performance and long service life.
2. The emissions of DEUTZ diesel gensets have reached the Europe | | or | | | standard.
3. Equipped with a new type of supercharger, with functions of backflow, well adapt to the plateau and high altitude regions
4. DEUTZ company provides quality assurance for all series of products.
5. DEUTZ company has built a professional service network all over the country, which provides after-sales services and supply spare parts for 24 hours a day.

Instructions for DEUTZ generator set maintenance 

1. We should discharge water in oil-water separator and check the level of the start-up battery electrolytic liquid after DEUTZ gensets runs for every 50 hours;
2. We should check the valve clearance and check the fuel injectors after DEUTZ’s new generators run for 200~300 hours,;
3. We need to check and adjust the transmission belt, replace them when necessary, check and clean the radiator chips and discharge the mud in fuel tank after DEUTZ gensets run for every 50 hours;
4. We need to replace lubricating oil and lubricating oil filter after DEUTZ gensets run for every 600 hours or at least every 12 months; the frequency of replacing the lubricating oil depends on the quality of the lubricating oil, the content fuel sulfur and consumption of lubricating oil by the generating unit.
5. We need to replace the oil-water separator and fuel filter, check whether the supercharger is leak, check whether the air inlet pipeline leaks, check and clean the fuel pipe after DEUTZ gensets run for every 800 hours;
6. Adjust the valve clearance after DEUTZ gensets run for every 1200 hours; replace the air filter and cooling fluid, thoroughly clean the water tank radiator chips and channels after DEUTZ gensets run for every 2000 hours;
7. Check the fuel injector, wash the turbocharger overhaul and overhaul engine equipment after DEUTZ gensets run for every 2400 hours.

Application of DEUTZ gensets

The installed capacity of Deutz engines has achieved rapid development in China. The application scope of DEUTZ engines is broad, including the commercial vehicles, engineering machinery, forklifts, agricultural machinery, compressor and ship, etc.

Installation and chamber design of DEUTZ generators
1. DEUTZ gensets are installed on the concrete floor.
1) We should pour a reinforced concrete base over the floor.
2) The concrete base should pass one month pressure test of over 173 kpa.
3) The concrete base should be at least 150 mm above the floor, with an extension of at least 150 mm per side along the chassis of the set,
4) The cement base should be embedded with the "J" or "L" type anchor bolt.
2. DEUTZ gensets are fixed on the chassis type fuel tank:
1) The shock absorber must be equipped between engine and fuel tank.
2) The structure and strength of the tank must be able to support static load and dynamic load of the sets.
3) We must keep a certain distance between the bottom of the tank and the ground, so as to facilitate the maintenance.

Chamber design of DEUTZ gensets

1) The sets should be in horizontal layout, and they can be in longitudinal layout when they are limited by the building site.
2) When the chamber is adjacent to the control chamber, the outlet end of the generator and the cable trench should be close to the transformer chamber.
3) The battery should be close to the side of the start-up motor
4) The chamber should have enough inlets for fresh air. The duct of the hot air and smoke should be stretched out to the outdoor, air inlet should be placed by the side of the motor, and the air outlet should be installed in the side of the tank.
5) The chamber should adopt comprehensive control measures for the noise removal of sets and sound insulation of chambers.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...