Skip to main content

Archive

Show more

How to Prevent Costly Rear Main Seal Comebacks



The most labor-intensive seal to replace on any engine is the rear main seal. There are no shortcuts or quick fixes if the seal has expired. On most modern engines, the seals failure is due to a condition inside the engine or a component connected to the back of the engine.

PTFE Rear Main Seal

Solving why the seal failed in the first place is critical to preventing a labor-intensive comeback. Here are six questions you should be asking yourself before, during and after a rear main seal job.
Is it the rear main seal that is leaking?

It might not be. On most engines, oil leaks can occur above and below the rear main seal. It could be a leaking oil pressure sensor, oil pan gasket or galley plug near the seal that causes oil to come from the bell housing. Adding dye to the oil can help reveal where the oil is coming from.
Is the PCV system clogged or blocked?

Most rear main seals have a lip that rides on the shaft. The pressure inside the crankcase will push the lip onto the shaft. Too much pressure will eventually cause the lip to balloon and allow oil to pass. If the Positive Crankcase Ventilation (PCV) system is blocked, it will increase the pressures inside the crankshaft and push out the seal. Also, if the engine is supercharged or turbocharged, excessive blowby due to worn or damaged piston rings can cause increased crankcase pressure that can also damage the rear main seal.

Rear Main Seal
What is the condition of the oil?

Most oils have chemicals in their additive packages that will condition the seals in the engine. If the oil is not changed regularly, it will cause the seal to degrade. The seal conditions are depleted over time along with buffers in the oil. The lip that rides on the crankshaft will become stiff and will not be able to seal itself against the crankshaft.
What is the condition of the crankshaft?

The condition of the surfaces that the rear main seal rides on is critical. Any imperfections or wear on the crankshaft can cause a leak. There are sleeve kits that can be installed on the crankshaft to restore the surface.

Rear Main Seal
Did you follow the directions that came with the seal?

Some rear main seals need to be installed dry. These seals have a polytetrafluoroethylene (PTFE) coating on the lip seal that needs to be dry and seat to a dry surface on the crankshaft. The seal will transfer a layer of PTFE to the crankshaft surfaces that the lip will ride on. The transfer layer prevents wear while sealing better than a silicone or Viton material. If the seal is installed with a coating of oil, it will start to leak in a few miles.
Are there alignment issues?

If there are any alignment problems with the bell housing or input shaft of the transmission, they can cause stress on the rear main seal. Make sure you check the input shaft on a manual transmission for play. On vehicles with automatic transmissions, check the flex plate for lateral runout or damage.


Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz