Description and Function of the Volvo System Components



Description and Function of the Volvo System Components


Description and Function of the System Components

Anti-icing vessel

The aim of the anti-icing device and the anti-icing vessel is to provide the compressed air with anti-icing fluid. The anti-icing fluid mixes with any moisture in the compressed air, prevents the fluid mixture from freezing and allows it to be drained off.

Function

When the compressor charges the braking system a partial vacuum is formed in the anti-icing vessel that allows it to draw air through an inlet in the vessel housing.


This inlet air is led via a tube down into the anti-icing fluid. When the air rises through the fluid in the form of bubbles it carries with it evaporated fluid to the upper part of the vessel. The air and the evaporated fluid is then drawn through a pipe to the compressor inlet and thus enters the braking system.



Single tower dryer, function

Charging phase

Air is forced from the compressor (1) to the air dryer inlet (2).

From here, the air passes through the drying agent in the vessel (3). The drying agent comprises porous balls called zeolites that have the ability to remove moisture from air. The dried air is then forced through the outlet (4) to the dry tank (5) and then on to the primary tank (6).

Cycle phase

When the compressed air system has reached full operating pressure, the pressure regulator (7) opens in answer to an air impulse from the drain valve (8) in the air dryer. The dry air from the dry tank (5) then blows back to the air dryer through the drying agent and carries with it any condensate out through the drain valve (8). A check valve (9) prevents air in the primary tank from flowing back to the air dryer when it cycles. There is a heating coil around the drain valve controlled by a thermostat. The heating coil prevents ice from forming in the drain valve.


Pressure regulator

There are different types of pressure regulator depending on the type of air drying system and compressor used in the installation. In installations with an anti-icing system that includes an alcohol vessel, or installations where small air volumes are used, we recommended that a pressure regulator

(1) with dump valve be installed. This is done to prevent air from recirculating back to the compressor

(2) and being heated. This shortens compressor life.

1 Pressure regulator

2 Compressor

3 Anti-icing injector

4 Check valve

5 Wet tank

6 Safety valve

7 Drain tap

8 Safety valve

NOTICE! If an air dryer is used in the installation, a dump valve is usually included in the air dryer system.



Pressure regulator

For use together with anti-icing injector:

1 Inlet from compressor

2 Outlet to wet tank

3 Dump outlet

4 Piston

5 Control impulse from wet tank

6 Check valve

7 Dump valve


Safety valves

The compressed air system must be equipped with a number of safety valves in order to protect the system against excess pressure (refer to the Design and Function of the Compressed Air System page 120 section in this chapter). Safety valve opening pressures vary depending on the parts they are protecting and the type of compressor the vehicle is equipped with. The objective of the valve (9) is to protect the compressor from excess pressure. Valve 9a is installed on the primary tank.



Safety valve, function



Pressure from the part of the system the valve protects reaches the safety valve via the inlet (1). When pressure exceeds valve opening pressure a passage between the inlet (1) and the outlet (3) is opened by a ball (2) that compresses a spring (4) and allows excess pressure to escape to atmosphere.


Drain valve for compressed air tank

All compressed air tanks must be fitted with manual drain valves to allow condensate to be drained. The tanks must be drained regularly in order to check air dryer function and to avoid any moisture ingress in the braking system. Condensate must be drained daily on vehicles with anti-icing devices.

Compressed air tank

Air from the compressor is stored in compressed air tanks and is delivered from the tanks to the various parts of the regulator system. Braking system tanks may be manufactured in aluminum alloy or steel and have a maximum pressure of around 10 bar (145 PSI).

Check valve

The function of the check valve is to ensure flow in one direction. Check valves are used in the delivery system. The check valve (No. 8 on the primary tank, refer to Design and Function of the Compressed Air System page 120 section in this chapter) prevents air from flowing from the primary tank through the drain valve in the air dryer when the compressor is idling.





Cooling Coil and Pipe Dimensions

In order to cool compressed air from the compressor there must be a cooling coil or sufficiently long pipe in the delivery system installed immediately after the compressor air outlet. The cooling coil should be located in a well-ventilated space; pipe length is governed by how well ventilated the space is once the coil is installed. If an inner pipe diameter of 16 mm (0.63") is used in the supply system from the compressor, a 4 m (13.1 ft) long cooling coil will be necessary. If an inner pipe diameter of 22 mm is used, the cooling coil need only be 2.5 m (8.2 ft) long. A cooling coil is used because the dump valve in the pressure regulator or air dryer has a maximum operating temperature limit. Volvo Penta provides pressure regulators to D9 - D16 Volvo engines as accessories that have an operating temperature of maximum + 50 °C (100 °F). If the cooling coil is not installed on the engine, a flexible hose must be installed between the compressor and the cooling coil. The flexible hose must be oil resistant and suitable for hydraulic fluid in order to withstand the pressure.


Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...