Skip to main content

Archive

Show more

Sound Absorption of Diesel Engine



Sound Absorption of Diesel Engine


Measurement methods

ISO 3744-1994, DIN 45635 part 11

Volvo Penta engine sound power levels are measured in a semi echo-free chamber. The ceiling and walls are covered with sound absorbing wedges. The engine is placed on a hard, reflection floor. By using the chamber, sound propagation equivalent to open field conditions is ensured.

The measurements are taken according to the international standard ISO 3744-1994 for engines with a cylinder volume of 9 liter (2.4 US gals) or more. Measurements of 420-722 engines are taken according to DIN 45635 part 11 or ISO 6798. The sound pressure level is determined by using several microphones arranged in a geometric pattern around the engine. Sound power level is then calculated on the basis of the average sound pressure level. Engine noise is measured during different engine speeds and load conditions. Noise from exhaust, inlet and fan are not included in the noise measurements. This means that the indicated sound power only comprises the noise emitted by the engine structure. Sound data for the entire industrial engine range can be found in the Sales Support Tool, Partner Network.

Diesel Engines Noise

Characteristics

A Volvo diesel engine is a complicated noise source. Dynamic forces cause vibrations and therefore noise emissions. Apart from the actual engine structure, the exhaust and inlet systems along with auxiliary devices contribute to total engine noise level.

Engine noise

Engine noise is the noise emitted from the engine structure. The pie chart below shows how large a relative part of total engine noise emissions given engine components have. Engine noise is created by forces that arise during the combustion process and the mechanical shocks between pistons and liners, valves and gear wheels etc. When a new engine is designed, a great deal of effort is put into minimizing engine noise. The most important means for achieving this is optimizing the injection system, controlling engine block stiffness and special treatment of the gear wheels in the engine timing system. Sound dampening materials can be placed on large noise emitters such as the oil sump and valve cover. Engine noise in an installation is usually reduced by screening off the engine. Such screening can be made even more effective by lining it with absorbent material. Usually, the level of screening is governed by engine cooling capacity. Finally, engine noise is to a large extent dependent on engine speed. For a given power an engine with low rpm is preferable to one with high rpm.

Exhaust Noise

Without a muffler, exhaust noise is the absolute largest source of noise on a diesel engine. High pressure pulses from combustion causes the exhaust flow to oscillate. On a six-cylinder four-cycle

engine, exhaust noise basic frequency is equivalent to three times engine rpm. This means that the muffler in most applications must have a high silencing capability across a wide frequency range.  The two most usual diesel engine muffler types used are:

- Absorbing mufflers

Absorbing mufflers have a chamber that is covered with sound absorbing material. Acoustic energy is transformed into heat in the absorbent material. This type of muffler has its best dampening ability in the medium to high frequency range.

- Expansion mufflers

The inside of the muffler is constructed so that sound is reflected, which reduces the acoustic force transmitted through the muffler. By allowing the pipe to discharge into a chamber and then leading exhaust gasses through several chambers, good sound dampening is achieved across a broad frequency range.

The price paid for good sound dampening in both muffler types is a higher back pressure in the exhaust system. The development of mufflers is often a compromise between acceptable back pressure and necessary noise reduction. Volvo Penta provides both muffler types. Their use ensures large noise reduction and low back pressure


Inlet Noise

As is the case with the exhaust system, pressure variations in the inlet system causes the airflow to oscillate. These pressure variations are of course much lower than those in the exhaust system. On modern turbocharged engines the compressor functions as an effective sound muffler. The pressure waves (noise) are dispersed by the rotating compressor blades. This means that inlet noise does not have any practical significance on Volvo Penta engines.

Auxiliary Noise

The cooling fan is one of an engine's largest noise sources. According to measurements the sound power level increases by 2 to 3 dBA when a fixed fan is used. Because fan noise is relative to engine rpm, it is necessary for the radiator to have a large capacity. An efficient radiator allows fan speed, and thus also noise, to be reduced. On applications where maximum cooling capacity is not a constant requirement, thermostatically or viscously coupled fans may be used. Viscously coupled fans are available as accessories for most Volvo Penta engines for mobile applications. Other equipment such as generators and air compressors have less significance compared to the fan when it comes to noise.


Structure Borne Noise

In many applications engine vibrations that affect the engine bed can cause sound emissions from connected structures. In many installations this can be a bigger problem than noise from the engine itself. By using resilient engine mounts the forces influencing the engine bed are reduced and therefore also frame noise. In the case of insulation for heavy vibrations, the engine bed must be at least 10 times as stiff as the insulator.









Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...