Volvo Penta Engine Maintenance Guides




Volvo Penta Engine Maintenance Guides


General inspection

Make it a habit to give the engine and engine compartment a visual inspection before starting the and after operation once the engine has stopped. This will help you to discover quickly if anything abnormal has happened, or is about to happen. Look especially carefully at oil, fuel and coolant leakage, loose bolts, worn or poorly tensioned drive belts, loose connections, damaged hoses and electrical cables. This inspection only takes a few minutes and can prevent serious malfunctions and expensive repairs.

WARNING!



Accumulations of fuel, oil and grease on the engine or in the engine room is a fire hazard and must be removed immediately they are detected.



WARNING!



If an oil, fuel or coolant leak is detected, the cause must be investigated and the fault rectified before the Volvo engine is started.

IMPORTANT!

Remember the following when washing with a power washer: Never aim the water jet at radiators, charge air cooler, seals, rubber hoses or electrical components.



Air Filter, Check and Change



The engine is equipped with electronic air filter indication. The control unit provides an output signal which is announced as a warning on the instrument panel. The warning indicates a pressure drop in the air filter, which must then be checked and possibly changed.

Scrap the old filter. No cleaning or re-use is permissible

In continuous operation, the filter should be checked every 8 hours. For operations in extremely dirty environments such as coal mines and rock crushing mills, special air filters must be used.

Charge Air Pipe, Leakage Check

Inspect the condition of the charge air hoses, hose union    s and clamps for cracks and other damage. Change as necessary.

IMPORTANT!

Clamps must be tightened using a torque wrench to 9 ±2 Nm (6.6 ±1.5 lbf.ft.).



Drive Belt and Alternator Belt,

Inspection



Inspections must be carried out after operations, while the belts are hot. You should be able to depress the alternator belt and the drive belt about 3-4 mm between the pulleys.



The alternator belts and drive belts have automatic belt tensioners and do not need to be adjusted. Check the condition of the drive belts. Replace as necessary; refer to Alternator Belt, Change page 51 and Drive Belt, Change page 50.



Drive Belt, Change

1 Disconnect the main switch(es) and check that the engine is not connected to system voltage.

2 Remove the fan guard and fan ring round the cooling fan.

3 Remove the belt guard.

4 Place a 1/2" square wrench in the belt tensioner (1). Lift the wrench and remove the drive belt.

5 Thread the drive belt round the fan and remove it.

6 Check that the pulleys are clean and undamaged.

7 Thread the new drive belt over the fan.

8 Lift the 1/2" wrench and install the new drive belt.

9 Install the belt guards.

10 Install the fan guard and fan ring round the cooling fan.

11 Start the Volvo engine and perform a function check.

Alternator Belt, Change



IMPORTANT!



Always replace a drive belt that seems worn or is cracked.



1 Disconnect the main switch(es) and check that the engine is not connected to system voltage.

2 Remove the fan guard and fan ring round the cooling fan.

3 Remove the belt guard.

4 Place a 1/2" square wrench in the belt tensioner (1). Lift the wrench up and lift the water pump drive belt off.

5 Place a 1/2" square wrench in the belt tensioner (2). Press the wrench down and remove the alternator belt.

6 Check that the pulleys are clean and undamaged.

7 Press the 1/2" wrench in the belt tensioner (2) down and install the new alternator drive belt.

8 Lift the 1/2" wrench in the belt tensioner (1) and reinstall the water pump drive belt.

9 Install the belt guards.

10 Install the fan guard and fan ring round the cooling fan.

11 Start the engine and perform a function check.


Lubrication System

Oil change intervals may vary according to the lubrication oil grade, fuel sulfur content and running conditions.

Refer to Technical data, Lubrication system.

The oil change interval may under certain conditions be increased. To see if the engine complies Volvo Penta oil analysis needs to be performed. Contact your Volvo Penta dealer for further information.
NOTICE! Oil change intervals must never exceed a period of 12 months.



Oil level, checking and topping up



The oil level must be inside the marked area on the dipstick and must be checked daily before the first start.

Top up with oil via the filler opening, please refer to Maintenance page 47. Check that the correct level has been achieved. If the engine is stationary, wait for a few minutes to allow the oil to run down into the oil pan.

The oil level can be read both when the engine is stationary (the STOP side of the dipstick) and with the engine running (the OPERATING side of the dipstick). Do not fill up above the maximum oillevel. Only use a recommended grade of oil, please refer to Technical Data page 69.

The oil level sensor only measures the oil level at the time when the ignition is turned on. In other words, not continually during operation.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...