Exhaust and Electrical System of Diesel Engine



This is the final part of checking and adjusting Deutz 226B series diesel engine for delivery beginning. It mainly includes checking exhaust, turbocharging and inter-cooling system and electrical system. 
3. 9. 2 Exhaust

The three - cylinder or four - cylinder diesel engine adopts unitary exhaust manifold, and the six - cylinder engine adopts inserted exhaust manifold which is made up of two parts ( every part for three cylinders) and sealed with narrow width ring. The joint between exhaust manifold and cylinder head is sealed with stainless steel gasket, the convex surface of which should face to the cylinder head.  The torque for tightening nut is 45 t 5Nm.

The exhaust resistance of diesel engine should be as small as possible; therefore the exhaust manifold must have sufficient sufficient or area and with bends as few as possible, because the performance of engine will be influenced obviously if the exhaust resistance exceeds a certain value. The sum of the resistances of exhaust main and muffler should not be more than 7.5kPa for natural aspirated engine, and not he more than 5kPa for turbocharged engine.

3. 9. 3 Turbocharging and inter - cooling system

Turbocharger: Both turbocharging models and the turbocharging inter - cooling models of the 226B series engine employ the radial flow exhaust turbocharger. See the accessory list for the those models.  The oil lubricating and cooling the turbocharger flows into the turbocharger from the main oil passage then directly back into the crankcase.

The exhaust turbocharger is a kind of running mechanism at its high speed and high temperature. The immediate halt when the engine is running at high speed and with large load is strictly forbidden.  The right way is to decrease the load and the speed gradually and let the engine run idly for another 5 -10 minute so as to avoid any damage to the turbocharger bearing. After the turbocharger is disassembled, some clean engine oil should be put at the oil inlet during the mounting process.

Charging air cooler (intercooler)

The temperature will go up after the air goes through the turbocharger and gets pressured. The intercooler of the 226B turbocharging inter - cooling engine features: air - air cooling. Is used to lower the pressured intake air temperature.

Air - air cooling intercooler ( delivered conforming with the contract) , generally speaking, is assembled together with the circulating water radiator, cooled by fan. The intercooler be placed at the hack of the radiator. The intercooler could also be placed in line with the radiator, determined by the overall fitting mechanism.

The maximum acceptable flow resistance ( supercharger to intercooler/ intercooler to engines) then the pressured air from the supercharger is passing through the pressure pipe should be less than 2kPa. The flow resistance while going through the intercooler should be less than 5.0 - 5. 5 kPa.  So the limit value of the total resistance when the pressured air is passing through pressure pipe and intercooler is 7. 0 - 7. 5 ( kPa) ,

3. 10 Electrical system

The system is consisted of starter, chargeable generator, control instrument and storage battery. The service voltage is 24V or 12V, subject to the choice of the customers.

Starter: the starter is a DC motor controlled by electromagnetism. Without specific requirement, the rated power is 4kW or 6kW at the working voltage of 24V and 2. 7kW or 4kW at the working voltage of 12V.

Generator: The generator is a kind of silicon rectifying generator equipped with transistor adjuster. The rated voltage is 28V or 14V. The generator is connected paralleled with the storage battery.  The generator is self - excited when working.

Flame preheating unit ( OPT) :the unit is a cold - starting auxiliary equipment used in cold weather and is composed by temperature sensor, solenoid valve,flame preheating plug, electronic control device and preheating indicator fitted to water outlet pipe ( principle diagram  shown in fig27) . The fuel enters preheating plug from the low pressure fuel delivery pipe and is  ignited by electric heating ,and the flame enters air inlet pipe and heats the air . The process is  perform automatically by control system. The unit controls automatically the glowing time and flame preheating time of the preheating plug according to the ambient temperature. The drive can start the engine after the preheating indicator give out signal.







Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...