Maintenance of Diesel Generator in Winter


As a emergency standby power supply after power failure, diesel generator sets are in standby state in most cases. Once the power is cut off, whether the generator set can start and supply is the key of playing as an important role during power supply. Otherwise, it will lose its meaning as a backup power source. Therefore, in order to make sure that diesel generator can be started successfully during power cut, it is necessary to maintain diesel generators in daily use.

Below are some tips for users to maintain diesel generator.

1. When the generator is in operation, all screens should be locked and the key shall be kept by hand. It is especially important not to leave the key in the lock.

2. Note that insulation tools should be used to ensure circuit safety when connecting or disconnecting the circuit.

3. Check engine starting motor batteries and wiring for metal objects. Clean up immediately.

4. Once the generator has a major fault, can press the control screen emergency stop button emergency shutdown. (this method is not advocated because frequent adoption can cause damage to the equipment.)

5. Before the generator stops, pay attention to load separation, let the diesel generator set idling for a period of time until the complete shutdown. In addition, the forced shutdown of the generator can easily cause damage to the unit by installing part of the unit with the stop valve, or by turning off the key switch of the control screen.

6. Generator monthly maintenance content:

A. Clean up the dust on the surface of the unit, etc.

B. Check whether the speed control rod is flexible and lubricate the connection points;

C. Change cooling water, measure PH value before and after replacement (normal value is 7.5-9), and do a good record of measurement, if necessary, add drug treatment;

D. Check the tension of fan and charger belts and adjust them if necessary

E. If the generator is used in important occasions, the no-load test should be started for at least 10 minutes per week, and the half-hour test with load should be done every six months.

Besides daily maintenance, how to keep diesel generator safe in winter or cold weather is also important.

1. Selection of diesel oil Carefully

Light diesel oil with low freezing point and good ignition performance should be selected in winter, and the freezing point of diesel oil should be lower than the local minimum temperature of 7-10 in the current season. Because the low temperature in winter will reduce the flow of diesel oil, increase the viscosity that will lead to uneasy spray. As a result, it is easy to cause poor atomization due to the diesel can not be fully burned, resulting in the power of diesel generators decreased and waste.

2. Do not release water too early or release water without cooling water

Before flameout should idle operation, waiting for cooling water temperature to 60 , water is not hot and then rest assured. If the cooling water is released prematurely, the body will suddenly shrink and crack when the temperature is high. The residual water should be discharged thoroughly when discharging water to avoid the expansion of the body.

3. It is not suitable to start with open fire

Do not remove the air filter, with cotton yarn dipping with diesel fuel ignited to make a fuse placed in the intake pipe to implement combustion booster. In the starting process, the dust-containing air of the outside world will inhale directly into the cylinder without filtration, forming abnormal wear of the piston, cylinder and other parts, and will also form the rough operation of diesel engine and harm the machine.

4. The engine should run at low speed for 3-5 minutes after starting in order to raise the temperature of the diesel engine, check the working condition of lubricating oil, check the normal operation before it can be put into normal operation. In the operation of the diesel engine, the service life of the valve assembly will be affected by reducing the sudden acceleration of the speed or stepping on the throttle to the maximum operation, otherwise the long time will affect the service life of the valve assembly.

5. Attention should be paid to body insulation

Winter temperature is low, easy to make diesel engine operation cooling excessive. Therefore, heat preservation is the necessary measure to prolong the life of diesel generator in winter. In the northern region, diesel generators should be equipped with insulation cover and thermal insulation curtain and other cold-proof equipment in winter.

6. It is not advisable to bake oil bottom with open fire

Avoid causing oil in the oil pan to degenerate, even scorch, smooth function decline or thorough loss, and then aggravate machine wear. Low freezing point oil should be used in winter, and the engine oil temperature can be raised by using water bath outside the machine to warm up the engine oil.




Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz