Skip to main content

Archive

Show more

Diesel Engine Cylinder Head Installation and Removal



The object of the measurement is to determine selection of the cylinder head gasket. Clean the mating surface, the cylinder block sealing surfaces and the cylinder head. Use cleaning spirits and 885516 Gasket scraper. Install spacers (3) and 9998678 Gauge rod (1) on the engine block sealing surface. Set the dial indicator (2) to ”0”.

15 NOTICE! All pistons must be measured at TDC. Piston height above the Volvo engine block must be measured at measuring points (1) and (2) on all pistons. Pay attention to the measuring points, since the piston crown is domed.

16 Check that the piston is in its uppermost position, TDC. Place the dial indicator on the piston at measuring points (1) and (2). Read off and note the value on the dial indicator.

17 Compare the highest noted value with the table below. Determine the appropriate cylinder head gasket.
18 NOTICE! Check the contact surface before installation. Pay attention to the guide sleeves (1).
19 Position the cylinder head gasket with the marking toward the flywheel.
Cylinder Head, Installation

20 Lift the cylinder head into place. Pay attention to the guide sleeves.
21 NOTICE! Use new cylinder head bolts.
Lubricate the cylinder head bolts. Install the cylinder head bolts.
NOTICE! Tighten the bolts in in sequence, as
illustrated.
Tighten in three steps:
Step 1: 50 Nm (36.9 lbf. ft.)
Step 2: 130 Nm (95.9 lbf. ft.)
Step 3: 90°
22 Install the pushrods.
Rocker arm bridges and rocker arms,
installation
23 NOTICE! The push rods must not be under compression due to valve overlap during installation.
Install the rocker bridge with rocker arms. Align it with the pushrods and valves.
Tightening torque: 30 Nm (22.1 lbf. ft.)
24 Connect the fuel return line (1). Hold the adapter secure (2) and fit the hollow screw (3).
Tightening torque: 29 Nm (21.4 lbf. ft.)
25 Set the valve clearance according to Valves, Adjustment page 49.
26 Install the injectors according to Injector, Change page 123.

27 Install the common rail unit according to 23-7, Common Rail, Change.
28 Install the inlet manifold according to Intake Manifold, Change page 143.
29 Install the exhaust manifold according to Exhaust Manifold, Change page 152.
30 Install the turbocharger according to Turbo, Change page 174.
31 Install the thermostat housing according to 26-2, Thermostat Housing, Change.
32 Install the air filter housing.
33 Install new oil filters and fill with engine oil according to Oil filter, Change page 94.
34 Fill with coolant according to Coolant, Change page 187.
35 Turn the main switch on.
36 Start the engine and perform a function check.

Cylinder Head, Removal
TAD752GE, TAD753GE, TAD754GE
Tools:
885516 Gasket scraper
9998678 Gauge rod
NOTICE! The main switch must be in the off position before work is begun.
1 Cooling system drained; refer to Coolant, Change page 187.
2 Oil drained.

Removal

3 Remove the air filter housing.
4 Remove the turbocharger according to Turbo, Change page 174.
5 Remove the exhaust manifold; refer to Exhaust
Manifold, Change page 152.
6 Remove the inlet manifold; refer to Intake Manifold, Change page 143.
7 Remove the thermostat housing; refer to 26-2, Thermostat Housing, Change.

IMPORTANT!

Work on the fuel system demands exceptional cleanliness. Install protective plugs in open connections.
8 Remove the common rail unit according to 23-7, Common Rail, Change.
9 Remove the injectors; refer to Injector, Change page 123.
Rocker arm bridge, removal
10 Remove the cable holders (2 pcs.) and move them aside.
11 Undo the rocker arm bridge bolts alternately.
12 Remove the rocker arm bridge with rocker arms.

13 Mark up the valve yokes.
14 Remove the push rods (1).
15 Remove the valve yokes (2).
16 Remove the wiring connectors (1) and the cable holder nuts (2).
17 Lift away the wiring.

18 Remove the injector sleeve.

19 Remove the cylinder head bolts.
20 Attach a lifting eye to the front of the cylinder head.
21 Connect straps to the lifting eyes and lift the cylinder head to remove it.

Cylinder head, installation

Cylinder head gasket
22 The object of the measurement is to determine the selection of cylinder head gasket.
23 Clean the mating surface, the cylinder block sealing surfaces and the cylinder head. Use cleaning spirits and 885516 Gasket scraper.
24 Place spacing washers (3), 9998678 Gauge rod
(1) on the engine block sealing surface and set the dial indicator (2) to ”0”.

NOTICE! All pistons must be measured at TDC. 25 Piston height above the engine block must be
measured at two points (1) and (2) on all pistons. Pay attention to the measuring points, since the
piston crown is domed.

26 Check that the piston is in its uppermost position, TDC.
Place the dial indicator on the piston at measuring points (1) and (2).
Read off and note the value on the dial indicator.

NOTICE! Make sure the surface is clean before application. 28 Position the cylinder head gasket with the marking toward the flywheel.
Pay attention to the guide sleeves (1).

Cylinder Head

29 Lift the cylinder head into place. Pay attention to the guide sleeves.


NOTICE! Use new cylinder head bolts.
30 Lubricate the cylinder head bolts.
31 Install the cylinder head bolts.
NOTICE! Tighten the bolts in numerical order, as illustrated.
32 Tighten in three steps:
Step 1: 40 Nm (29.5 lbf.ft.)
Step 2: 95 Nm (70.1 lbf.ft.)
Step 3: 180°

33 Install the injector sleeve.
34 Check the harness seal.
35 Fit the wiring connectors (1) with lock washers, and tighten the plastic nuts (2).
36 Connect the harness terminal to the wiring connector
(1).
37 Allow the cable holder to hang free from the engine.
38 Fit the push rods (1).
39 Lubricate the valve stems.
40 Replace the valve yoke (2) in accordance with the earlier marking.



Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...