Steps to Proper Maintenance of Diesel Engine



As we know that a diesel generator is the combination of a diesel engine and a alternator (a synchronous AC generator) to generate electricity. It can be as prime power or backup power for electric power generation.

Engine is as the core component of the diesel generator. If you want to run it well, carefully maintenance is necessary. Today, we will talk about six stepsmethod for diesel engine maintenance.

1. Running-in/Grinding-in

This is the basis for prolonging service life. Both new and overhauled engines must be grinded according to the rules before they can be put into normal operation.

2. Clean fuel,  water, air and machine body

Diesel is the main fuel of the engine. If the diesel oil is not pure, it will make the precise matching body wear and tear, increase the matching body clearance, cause oil leakage, oil dripping, reduce the oil supply pressure, increase the gap, even cause oil path clogging and so on main failure.

If there is a lot of dust in the air, it will accelerate the wear of the cylinder sleeve, piston and piston ring. If the cooling water is not pure, it will block the water scale of the cooling system, which will hinder the engine heat dissipation, result in poor lubrication condition and severe wear of the body.

If the body appearance is not clean, it will make the surface corrosion and shorten the service life.

3. Enough diesel/oil, water and air

If the supply of diesel and air is not timely or interrupted, there will be some problems, such as difficult starting, poor combustion, power coastdown, and the engine can not run normally.

If the oil supply is insufficient or interrupted, engine lubrication will be poor, the body will wear seriously and even burning tile phenomenon. If the cooling water is not enough, the machine temperature will be too high, the power will decrease, the wear will be aggravated, and the service life will be reduced.

4. Make a regular inspection on fasteners for any loose condition

The bolts and nuts are easy to loosen due to the influence of vibration shock and uneven load during the operation of the diesel engine. There are all parts of the adjustment bolts should be checked to avoid causing loosening and damage to the body.

5. Inspection and adjustment

That is, diesel engine valve clearance, valve timing, fuel supply advance angle, injection pressure and ignition timing should be checked and adjusted, so as to ensure that the engine is always in good technical condition, only in this way can save fuel and extend the service life.

6. Proper use of diesel engine

Before starting, make sure that all lubrication parts shall be lubricated.

After starting, water temperature should reach 40 - 50 before putting into operation, long time overload or low speed operation is strictly prohibited. Before stopping, the load should be removed to reduce the speed. When the water temperature drops to 40 - 50 after the shutdown in winter, the engine with cooling water has been injected with antifreeze.

The maintenance of the engine should be done regularly at ordinary times to keep the machine in good condition.

Starlight Power - China's Largest Brand Engine OEM Cooperative Manufacturer

Starlight Power has a management team with advanced consciousness, strong youth and proficient business, taking the establishment of high-tech innovation enterprises as the starting point, insisting on "high starting point, high technology, excellent service", and actively collecting and absorbing advanced technology and advanced products at home and abroad. Constantly update the products.

In recent years, we have cooperated extensively with Swedish Volvo, American Cummins, British Perkins, Germany Deutz, Korea Doosan, Germany MTU, Ricardo, Shangchai, Yuchai, Weichai, Jichai, Tongchai, and Wudong and so on famous engine companies, and have become their OEM supporting factory and technology centers.

Starlight Power - Outstanding Achievement

Between 2010 and 2017, Starlight Cummins Series diesel generator won the National sales Championship for eight consecutive years, becoming Cummins largest OEM cooperative manufacturer in China.

Besides, Starlight company has been working with Yuchai Power since 2015. So far, it has been the core OEM partner of Yuchai Power in China. Yuchai engine is China famous engine brand, In 1994, Yuchai became the first Chinese company to be listed on the New York Main Board (NYSE: CYD)

Starlight company has been working with Shangchai Power for many years and has been the largest OEM cooperative manufacturer in China since 2009.

Starlight Volvo Series generator set, top 3 sales in Asia Pacific, is the core OEM partner of Sweden's Volvo company in Asia Pacific region.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...