Skip to main content

Archive

Show more

How to Adjust Valves of Cummins NT Engines



This post is mainly written to introduce how to adjust crosshead, injector and valves of Cummins NT diesel engines correctly. Pay attention to reading and you will learn more.

Crosshead Adjustment

Note: Crosshead adjustment should always be made before attempting to adjust the valves.

1. Loosen the locknut on the crosshead adjusting screw. Turn the adjusting screw out at least one turn.
2. Hold the crosshead down against its mating valve stem. Turn the adjusting screw back in until it touches the valve stem. Hold the adjusting screw in this position and tighten the locknut.
3. Tighten the adjusting screw locknut to 25 to 30 ft-lb [34 to 41 N*m] torque.

Note: When ST-669 Torque Wrench Adapter is used, tighten the locknut to 22 to 26 ft-lb [30 to 35 N*m] torque.

4. Check the clearance between the crosshead and valve spring retainer 1 and 2. Fig. 2-19 with a wire gauge. Tighten must be a minimum of 0.025 inch [0.64 mm] clearance.

Valve Adjustment


The VSmarkets used when adjusting the injectors is also used when adjusting the valves; however, the valves to be adjusted are not on the same cylinder as the injector. See Table 2-3 for the correct valves to adjust.

Example: When 1-6 VSis used, the injector on cylinder number 3 is adjusted and the valves on cylinder number 5 are adjusted.

1. Loosen both locknuts on the intake and exhaust valve adjusting screws.

2. Insert the proper feeler gauge between the rocker lever and crosshead contact surfaces. (Fig.2-20). See Table 2-9 for valve clearance valves.

3. Turn the adjusting screw down until the rocker lever just touches the feeler gauge. Hold the adjusting screw in this position and tighten the locknut to 40 to 45 ft-lb [54 to 61 N*m] torque.

Note: When ST-669 Torque Wrench Adapter is used, tighten the locknut to 35 to 40 ft-lb [47 to 54 N*m] torque.

4. Always adjust the valves after the injector adjustment. Move to the next cylinder as indicated in Table 2-3 and repeat the adjustments until all injectors and valves have been set.

Adjust Injector and Valves (Torque Method For Top-Stop Injector Engines)



Timing Mark Alignment

1. Loosen the injector rocker lever adjusting nut on all cylinders. This will aid in distinguishing between cylinders adjusted and not adjusted.

2. Bar the engine in the direction of rotation until a valve set mark aligns with the mark or pointer on the gear case cover.

3. Check the valve rocker levers on the two cylinders aligned as indicated on the pulley. On one cylinder of the pair, both rocker levers will be free and the valves closed; this is the cylinder to be adjusted.

4. Adjust the injector plunger first, then the crossheads and valves to the clearances indicated in the following paragraphs.

5. For the firing order see Table 2-5 for Inline Engines.

6. Continue to bar the engine to the next VSmark and adjust each cylinder in the firing order.

Note: Only one cylinder is aligned at each mark. Two complete revolutions of the crankshaft are required to adjust all cylinders.



Injector Plunger Adjustment

The injector plungers must be adjusted with an inch-pound torque wrench to a definite torque setting. A torque wrench with a screwdriver adapter can be used for this adjustment.

Turn the crankshaft in the direction of rotation until one of the VSmarks are aligned with the pointer. Check both of the cylinders indicated on the pulley to see which valve rocker levers, this is the cylinder to be adjusted.

1. Turn the adjusting screw down until the plunger contacts the cup and advance an additional 15 degrees to squeeze the oil from the cup.

2. Loosen the adjusting screw one turn; then using an inch torque wrench with screwdriver adapter tighten the adjusting screw to the valve shown in Table 2-6 and tighten the locknut to 40 to 45 ft-lbs [54 to 61 N*m] torque. If ST-669 Torque Wrench Adapter is used, torque to 30 to 35 ft-lbs [41 to 47 N*m].


Crosshead Adjustment

Crossheads are used to operate two valves with one rocker lever. The crosshead adjustment is provided to assure equal operation of each pair of generator set valves and prevent strain from misalignment.

Valve Adjustment

The same engine position used in adjusting the injectors is used for settings the intake and exhaust valves. Adjust the injectors and the valves on the same cylinder at the same time.

1. While adjusting the valves, make sure that the compression release, on those engines so equipped, is in the running position.

2. Loosen the locknut and back off the adjusting screw. Insert a feeler gauge between the rocker lever and crosshead. Turn the screw down until the lever just touches the gauge and lock the adjusting screw in this position with the locknut. Tighten the locknut to 40 to 45 ft-lbs [54 to 61 N*m] torque. When using ST-669 torque to 30 to 35 ft-lbs [41 to 47 N*m].

3. Always make final valve adjustment at stabilized engine lubricating oil temperature. See Table 2-7 for the appropriate valve clearances.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...