Introduction of Governor in Diesel Generator



The function and type of diesel generator set governor

1. The function of the governor of diesel generator set

The function of the governor is to adjust the fuel supply automatically with the change of the external load of the diesel engine within the required speed range of the diesel engine, so as to keep the diesel engine speed basically stable.







When the diesel engine drives other working machinery (such as generator, pump, etc.), if the output torque is equal to the torque (drag moment) required by the working machinery to overcome the working resistance, then the engine is in a stable state (the rotational speed is basically stable). If the resistance moment exceeds the output torque, the speed of the diesel engine will decrease, and the diesel engine will stop working. When the output torque is greater than the resistance moment, the rotational speed will increase, if the new balance is not reached, the rotational speed will continue to rise and the "flying car" accident will occur. Because the resistance moment of the working machine will change frequently with the change of the working condition, it is impossible for the operator to adjust the fuel supply sensitively and in time, so that the output torque of the diesel engine can be adapted to the external resistance. In this way, the speed of the diesel engine will fluctuate violently, thus affecting the normal operation of the working machinery. Therefore, the diesel engine for construction machinery must be equipped with governor. In addition, due to the characteristics of diesel spatter pump itself, it is not easy to maintain stability at idle speed, and it is easy to overspeed or even "fly" at high speed. Therefore, the diesel generator governor must be installed on the diesel engine to keep its idle speed stable and prevent the phenomenon of "flying car" at high speed.

2. Type of governor

A. According to the different classification of governor regulating mechanism, it can be divided into four types: mechanical type, hydraulic type, pneumatic type and electronic type.

(1) ]mechanical governor
The sensing element of the mechanical governor is a flying block or a flying ball, which directly pushes the actuator. Simple structure, reliable work, widely used in medium and small power diesel engines.

(2) hydraulic speed governor

The pressure governor generally uses the flying block as an inductive element to push the piston to operate the hydraulic server. This governor has small induction elements and strong versatility. A few series of dimensions can be used to meet the requirements of tens to ten thousand horsepower diesel engines. It has good stability, high adjustment precision and large driving force, and is easy to realize automatic control of diesel engine. But the structure is complex, the craft request is high, suitable for the high power diesel engine.

(3) Pneumatic governor

The moving governor uses the diaphragm to induce the change of the vacuum of the inlet pipe, and then to promote the actuating mechanism. The governor has simple structure and high sensitivity at low speed, but the power is decreased due to the throttle valve installed in the intake pipe. Therefore, it is only suitable for low power diesel engines.

(4) electronic governor

The electronic governor converts the change of diesel engine speed into the change of electric quantity, and controls the actuator after sampling and amplifying. This governor can adjust the fuel supply before the speed of diesel engine changes obviously, and obtain high adjusting precision, and realize parallel operation without difference. Mainly used for diesel generator sets.

3. According to the speed range of the governor, it can be divided into three types: single program, two-pole type and whole course type.

(1) Single program governor

A single program governor works only at a certain speed (usually a calibrated speed). Suitable for diesel engine with constant speed, such as driving generator, air compressor, centrifugal pump and so on.

(2) Two-pole governor

The two-pole speed governor works only in the case of idle speed and calibrated speed of diesel engine. Mainly used in cars, to maintain idling stability and prevent high-speed "flying". In other cases, the operator operates the throttle to adjust the fuel supply.

(3 )Whole speed governor

The whole-course governor works in the range of diesel engine speed. After the operator chooses any speed according to the need of the operation, the governor can make the diesel engine work steadily at the speed automatically. It greatly improves the working conditions of the operators under the condition of frequent load changes, and also improves the working quality and production efficiency. Therefore, most construction machinery uses this governor.

The failure of the electronic governor will cause the performance of the diesel engine to decline so that the diesel engine can not run. If it can be clearly judged as the fault of the electronic governor, the power can be replaced by the governor. If it is a fault of diesel engine and its auxiliary system, it is possible to meet the operational requirements through the speed of the diesel engine, and the replacement of electronic governor will not solve the problem. Therefore, the cause of the failure should be analyzed through the comprehensive analysis of the system.

Signal of Insufficient magnetic speed sensor: When the rotational speed sensor signal is strong, it can resist the external pulse interference, and the rotational speed controller can measure the RMS signal above 3V output from the rotational speed sensor. When the voltage is lower than 3V, the clearance between the speed sensor and the engine should be reduced (the gap should be less than 0.45mm), which can increase the amplitude of the signal. When the voltage is still below 3 V, check if the magnetic properties of the speed sensor are too weak.

The cable or direct radiation control circuit signal is a great interference source, which will bring bad effect to the side speed system. The speed sensor should be connected with a shielded cable. Since the source of interference is different, it is recommended to use the shielded cable, and the metal plate of the speed controller is grounded or installed in the inner sealed metal clamp to protect against electron radiation. Use metal covers or metal containers to work better. Shielding wire is the most common anti-interference measure. If the generator is equipped with brush, the EDM interference can not be ignored, so special shielding measures should be adopted in the large disturbance environment.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...